Power lead routing
The power supply for this appliance is provided via AC power adaptor 230 VAC. The main cable terminates
at the rear Right hand side of the fire box. The length of the cable provided with the appliance is 1.65
metres. Care must be taken when siting the fire box not to trap the exposed main cable within the builders
opening.
Note: the power cable link to the transformer must be accessible for repairing handset and use with the
battery holder
The cable can be routed using the following two methods,
Method 1
Passing the cable through the side of the chimney breast. It is good practice to run the cable within a
sleeve of at least 15mm internal diameter, sealing the sleeve using a suitable sealant at the point the
sleeve / cable terminates the chimney masonry.
Method 2
Remove a channel out of the outer skin of the Dry / wet plaster of the chimney breast up to the main
power point. Again it is good practice to run the cable within a sleeve of at least 15mm internal diameter.
With power points that exceed the 1.65 metre distance, an optional 2.0 metre extension cable is available
Part No 7147.
The cable system consists of retro fitting plug sockets which offers the following options. (Please see figure
5).