background image

 

 

www.charltonandjenrick.co.uk 

17 

LT8229 (ISS 3) 

SECTION FIVE General Points (Users Instructions) 

Like all appliances incorporating an aerated burner a low frequency noise may be heard, particularly on the low 
setting, this is quite normal and does not affect the operation of the appliance. 

It is advised that a competent person service the Paragon Edge fire annually. The fire is more likely to provide 
trouble-free operation. 

Dulling and slight discoloration inside the firebox will occur adding to the realism of the appliance. This is normal. 

It is important that: - 

 

The chimney or flue is checked annually to ensure clearance of combustion products. 

 

Any  debris  from  the  chimney  or  flue  should  be  removed.  The  fire  should  be  allowed  to  cool  before  it  is 
removed. 

 

The fire must not be used if the glass panel is missing or damaged. 

 

The data badge is located on the rear of the door. 

The only user removable parts are: - 

 

Refractory Fire bed Components. 

 

Glass panel. 

 

SECTION SIX Appliance Data (Installation Instructions) 

Please note the Edge 3s is available Nat Gas only 

 

 

 

 

 

 

NATURAL GAS 

 

 

 

PROPANE GAS

 

Gas Type: 

 

 

 

CATEGORY I 

2 H

                 

   

CATEGORY I 

3 P

 

Gas Pressure:   

 

 

20 mbar +/- 1.0mbar 

  

               37 mbar +/- 1.0mbar 

Pressure Test Point Location: 

 

Gas inlet elbow  

 

 

 

Gas Input: 

 

 

 

5.2 kW Gross (Max) 

  

               5.0 kW Gross (Max) 

 

 

 

 

 

3.0 kW Gross (Min) 

 

               3.3 kW Gross (Min 

Injector: 

 

 

 

Mk 360  

 

 

               Mk 116  

Oxy pilot: 

 

 

 

2900 NGR 

 

  

               LPG 9264 

 

 

Gas Connection:  

 

 

8mm compression: semi-rigid or rigid 

NOX Class……………………………………………   

 

 

 

 

Data Badge located on the inside of the door.   

 

 

 

 

 

Summary of Contents for Paragon Edge

Page 1: ...tforservicelogandfuturereference For use in Great Britain Literature NO 8229 ISS 3 IMPORTANT This appliance is guaranteed for 12 months subject to conditions The 5 year extended parts warranty will only be valid if the annual service recommended in this manual has been completed and appliance has been registered online ...

Page 2: ...pposite page and ensure your installer has filled in the appropriate checklist This in no way reduces your statutory rights Your warranty commences from the date of purchase and you must retain your receipt or invoice as proof of a purchase date THIS EXTENDED WARRANTY SPECIFICALLY EXCLUDES GLASS AND SOFT REFRACTORY COMPONENTS THE BULB AND ANY BATTERIES Terms and Conditions 1 The appliance must be ...

Page 3: ...lations England and Wales All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme A Building Regulations Compliance Certificate will then be issued to the customer who should on receipt write the Notification Number on the Benchmark Checklist This product should be serviced regularly to optimise its safety efficiency and performance T...

Page 4: ...rtant For future reference we suggest you record the following details here and keep the receipt as proof of purchase This information may be asked for when you contact the helpdesk MODEL Edge Edge 3s GAS STOVE Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the back of the door of the appliance Retailer Name Address Date Of ...

Page 5: ...nd eye protection After handling wash hands and other exposed parts If a vacuum is used for cleaning the Logs or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these materials should be securely wrapped in polythene and be clearly labelled RCF waste These materials are not c...

Page 6: ... During the normal operation of the fire some black staining may appear on some parts of the fuel bed This is quite normal and adds to the appearance of the appliance However if excessive black staining does occur it may be due to the fuel bed being incorrectly laid This should be checked prior to contacting a service engineer Care must be taken to prevent any damage being caused to surrounding so...

Page 7: ... it is recommended that the standby button be used C The appliance can be switched off without using the handset by unplugging the transformer When the transformer is removed there will be a delay up to 3minutes after which double bleeps may be heard and shortly after the appliance will extinguish Ensure that the transformer is reconnected once the fire as been extinguished The appliance cannot be...

Page 8: ... door to disengage the lower magnets and lift the door upwards to remove Remove the 2 off M4 fixing nuts from the glass fixing bracket located at the top of the glass panel Remove the top fixing bracket why supporting the glass panel Lift the glass panel from within the bottom support bracket Lay some old newspaper under the area you are working on when the door is open Follow the instructions on ...

Page 9: ...let before cleaning or replacing any refractory material The fuel bed components are delicate and they should be handled with great care The loose Log shapes may be removed for cleaning They can be brushed very gently with a soft brush to remove dust or any deposits A vacuum cleaner may only be used after the loose Log shapes and vermiculite has been removed CARE SHOULD BE TAKEN TO AVOID DAMAGE TO...

Page 10: ...10 LT8229 ISS 3 Spread a thin layer of vermiculite over the burner plaque taking great care around the pilot area ...

Page 11: ...www charltonandjenrick co uk 11 LT8229 ISS 3 ...

Page 12: ...12 LT8229 ISS 3 ...

Page 13: ...www charltonandjenrick co uk 13 LT8229 ISS 3 ...

Page 14: ...14 LT8229 ISS 3 ...

Page 15: ...www charltonandjenrick co uk 15 LT8229 ISS 3 ...

Page 16: ... number 12 shape is only included with the Edge 3s fuel bed Failure to fit this shape correct could result in sooting deposits on the side glass window The shape should be place directly on the burner tray alongside the pilot shield ...

Page 17: ... combustion products Any debris from the chimney or flue should be removed The fire should be allowed to cool before it is removed The fire must not be used if the glass panel is missing or damaged The data badge is located on the rear of the door The only user removable parts are Refractory Fire bed Components Glass panel SECTION SIX Appliance Data Installation Instructions Please note the Edge 3...

Page 18: ...lt is 74 1 for Natural Gas and 71 4 for LPG Propane The gross calorific value of the fuel has been used for this efficiency calculation GasTec have certified the test data from which it has been calculated The efficiency value may be used in the UK Government s Standard Assessment Procedure SAP for energy rating of dwellings When unpacking the appliance please check the following items are include...

Page 19: ...991 However a guard conforming to BS6539 1984 must be used to protect young children the elderly or infirm This appliance incorporates a safety device in the form of an Oxygen depletion system IT MUST NOT BE ADJUSTED OR PUT OUT OF OPERATION THIS IS A NON SERVICABLE ITEM AND MUST BE EXCHANGED AS A COMPLETE ASSEMBLY USING ONLY THE ORIGINAL MANUFACTURER S PART A non combustible hearth must be provide...

Page 20: ...20 LT8229 ISS 3 ...

Page 21: ...ear exit on this model Class 1 Conventional Flue The chimney must have a minimum effective height of at least 3 metres Any permanent flue restriction or variable dampers are to be removed or locked fully open The chimney should be swept prior to installation if it has previously been used with solid fuel This is not necessary if the flue has previously been used with a gas appliance or if it is a ...

Page 22: ... rear vent closure plate The builders opening must be fully sealed using with the closure plate The width of the opening must be between minimum of 290mm to a maximum of 335 mm The height of the opening must be between a minimum of 550mm to a maximum of 560mm Clearances required when installing into a Inglenook opening Top Exit Using Register Plate Not Provided The appliance his provided with the ...

Page 23: ...onforming to BS1289 or BS EN 1806 The appliance is suitable for installation conforming to older versions of BS1289 The cross sectional area must not be less than 13 000mm2 The chimney vertical height must not be less than 3m and be correctly terminated To achieve the rear exit option the appliance gather hood will need to be removed The outlet spigot from with the rear vent kit will need to be at...

Page 24: ...24 LT8229 ISS 3 ...

Page 25: ...229 ISS 3 Note When installing the appliance using the above method The appliance must sit hard against the closure place This will allow 50mm of the rear spigot assembly to protrude into the catchment area Rear Vent kit installation 12 ...

Page 26: ...Distances from Non combustible materials The stove can be recessed in a suitable sized non combustible fireplace but a permanent free air gap of at least 50mm must be left around the sides and top and at least 50 mm at the back of the stove to obtain reasonable heat output and for access to the stove for removal and maintenance Clearance requirements to a combustible material Minimum hearth height...

Page 27: ...www charltonandjenrick co uk 27 LT8229 ISS 3 12 ...

Page 28: ... be used only externally of the appliance The appliance is supplied with a factory fitted isolation device to allow for an 8mm copper connection No further isolation point is required The new gas line must be purged of any debris prior to final connection to the appliance Gas inlet isolation device is located on bottom left hand side of the fire box the gas supply entry point is positioned at the ...

Page 29: ...ing the following two methods Method 1 Passing the cable through the side of the chimney breast It is good practice to run the cable within a sleeve of at least 15mm internal diameter sealing the sleeve using a suitable sealant at the point the sleeve cable terminates the chimney masonry Method 2 Remove a channel out of the outer skin of the Dry wet plaster of the chimney breast up to the main pow...

Page 30: ...ial that the existing fuel bed be removed and the new components are replaced correctly as a complete set Lay Log fuel bed as described under Users Section Warning It is important that the fuel bed components are positioned as shown in these instructions If the fuel bed components are not positioned correctly this may result in damage to the glass Once fuel bed is fitted refit the glass Locate the...

Page 31: ... 1997 and satisfies the heating appliance regulations 1991 however a fireguard conforming to BS6539 1997 must be used to protect young children the elderly or infirm The curing effect of heating the coals and other refractory components will cause an initial odour This is due to the starch used in the manufacturing process and is non toxic Any debris should be cleaned from the appliance A vacuum c...

Page 32: ...ey accordingly To Remove The Burner Carrier Assembly Turn off the main supply to the appliance Remove or lift up top plate Remove the decorative door assembly Remove the glass panel Remove the Loose shapes Shut off the restrictor elbow and disconnect the 8mm inlet nut Take out the two screws securing the burner carrier assembly to the Firebox Pull the complete burner carrier assembly forward until...

Page 33: ...ion nut on the supply pipe at the pilot Carefully pull off the ignition lead Disconnect the thermocouple at the end of the gas valve Remove the two fixing screws attaching the assembly to burner carrier Re assemble in the reverse order Replacement of the burner Assembly Remove the glass panel as described in the users instruction section Remove the Loose shapes and the air tray assembly Undo the t...

Page 34: ...pairing process with the power to the appliance turned off Make sure that the remote handset has batteries installed then turn the power on to the appliance on Within 30 seconds of power on press any button on the remote handset The LED on the handset will start to flash quickly indicating the pairing process has started If successful pairing is achieved then the LED will show 5 slow flashes If pa...

Page 35: ... list Edge CF version Image Description Part number Oxy pilot NG 2900 LPG 9264 NG 7280 LPG 2703 Injector NG 3208 LPG 2222 Silencer NG 7937 LPG none fitted Valve 6590 EDB 8080 Handset 8081 Earth lead 6776 Ignition lead 6646 9V transformer 7145 Rear liner 8114 ...

Page 36: ...liner 8115 Front glass Standard 8912 Non reflective 8113 Edge 3 S CF version Image Description Part number Oxy pilot 2900 7280 Injector 3208 Silencer 7937 Valve 6590 EDB 8080 Handset 8081 Earth lead 6776 Ignition lead 6646 ...

Page 37: ...jenrick co uk 37 LT8229 ISS 3 9V transformer 7145 Rear liner 8114 Side viewing glass LH 8537 RH 8536 Side glass gasket 8535 Front glass Non reflective 8113 Register your appliance online today to active your warranty ...

Page 38: ...facturer s instructions Hearth Requirements where fitted Is the hearth constructed from non combustible material Is the hearth a minimum of 12mm thick with a minimum floor to top surface of 50mm BS5871 or as per manufacturer s instructions Is the hearth for open fronted fires a minimum of 760mm wide and has 300mm projecting from the fire opening BS6871 or to manufacturer s instructions Mounting he...

Page 39: ...ays use the manufacturer s specified spare part when replacing controls SERVICE 01 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 02 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 03 Date Engineer name Company name Telephone No Gas safe register No Comments Signature SERVICE 04 Date Engineer name Company na...

Page 40: ... Bed Part No 8696 Glass Panel Part No 8113 Data Badge Spillage Label 10 minute text Warning Label Part No 1409 ID Label Packing Labels Owners Book 2 x AAA Batteries Part No 5487 Embaglow 7MM Nut Spinner Part No 5435 Remote Handset Bluetooth Part No 8081 9v Transformer Part No 7145 Spigot Gasket Flue Spigot Grommet solid 35mm 1092 Serial Number Inspector ...

Reviews: