28
LT8229 (ISS 3)
SECTION NINE To Install the Appliance (Installation Instructions)
CHECKING THE FLUE AND FIRE OPENING
•
Check that the chimney conforms to the required specifications as previously stated. Examine the condition
and carry out any remedial work including removing any debris from the base.
•
If the flue has been used for solid fuel it should be swept prior to the installation
•
Prior to installing the appliance a smoke test (using a smoke bomb) should be carried out to check that
satisfactory smoke clearance has been established.
If all the smoke is not drawn into the flue, pre-heat the flue with a blowtorch or similar and re-check. If there is any
uncertainty examine for the cause and, if necessary, seek expert advice.
No combustible material should be fitted inside the fireplace opening.
GAS SUPPLY ROUTING :-
Use rigid or semi
–
rigid tube to connect the supply. Determine the gas supply pipe route to the appliance before
installing the Stove.
Check the gas run to assess that the gas supply is capable of providing the required amount of gas and is in
accordance with the rules in force.
Soft copper pipe can be used to install the appliance. Soldered joints can be used only externally of the appliance.
The appliance is supplied with a factory fitted isolation device to allow for an 8mm copper connection. No further
isolation point is required.
The new gas line must be purged of any debris, prior to final connection to the appliance.
Gas inlet isolation device is located on bottom left hand side of the fire box, the gas supply entry point is positioned
at the rear bottom on left hand side. With the appliance fixing kit is a 35mm round seal should be cut and fitted
over the 8mm copper at the point the gas supply entry into the appliance assembly.
CHECKING GAS SOUNDNESS
Checking gas soundness and running pressure.
Turn on the supply to the appliance and check for soundness in accordance with the current codes of practice.
Turn off the gas supply at the external isolation valve.
Remove the pressure test point screw from the inlet elbow and connect the pressure gauge.
Turn on the gas to the appliance at the isolation valve.
Light the appliance as described in the user instruction section 2. Operating the appliance.
Check the inlet pressure is 20 mbar N.G. or 37 mbar LPG P/- 1.0 mbar with other appliances running.
Turn off gas supply, at the isolation valve. Disconnect the pressure gauge and replace the pressure test point screw.
Turn on the appliance and check the pressure test point for soundness with detection fluid.
Summary of Contents for Paragon Edge
Page 11: ...www charltonandjenrick co uk 11 LT8229 ISS 3 ...
Page 12: ...12 LT8229 ISS 3 ...
Page 13: ...www charltonandjenrick co uk 13 LT8229 ISS 3 ...
Page 14: ...14 LT8229 ISS 3 ...
Page 15: ...www charltonandjenrick co uk 15 LT8229 ISS 3 ...
Page 20: ...20 LT8229 ISS 3 ...
Page 24: ...24 LT8229 ISS 3 ...
Page 27: ...www charltonandjenrick co uk 27 LT8229 ISS 3 12 ...