www.charltonandjenrick.co.uk
23
LT7271 (ISS2)
Note:- When installing the appliance using the above method. The appliance must sit hard against the
closure place. This will allow 50mm of the rear spigot assembly to protrude into the catchment area.
Distances from combustible materials:
It is strongly recommended that any furniture or other combustible materials are kept at least 900mm clear from the
front of the stove.
Due to the fact that combustible shelves, timber fireplaces and beams have potentially thousands of possible
configurations in conjunction with stoves outset or inserted partially or fully into chambers, it is not possible to give
firm guidance on dimensions to these features. As a guideline, materials that are in ‘line of sight’ to the stove are
more likely to overheat due to direct radiation from the stove body than materials that are not in ‘line of sight’ (e.g.
with stove fully inside a chamber). Materials above the stove are more likely to overheat than materials alongside or
below. A guideline limiting temperature for solid timber (not surface finishes) is approximately 80-85 degrees C with
a normal ambient room temperature. Temperatures of combustible materials can be substantially lowered with a
simple heat shield constructed of a non-combustible material and small air gap between the shield and combustible
material.
Summary of Contents for PV5W