Gas Conversion From LP to NG
continued
Step 3: Check for Gas leak
Make sure you conduct a leak test before operating the grill after
conversion. Please refer to Page 16 on the manual on how to test
for gas leak.
Step 4: Adjustment of Control Valves for Main Burner.
a Remove the black rubber ring on the control knob
b Remove all control-knobs with 5/32” Allen wrench (provided)
c. Adjust gas valve through access hole at knob-bezel by inserting a flat head
screw-driver. Turn the screw driver clockwise (to tighten) until it stops. (Not: it
may already be fully turned so it will not turn further). Then turn it
counterclockwise (to loosen) for one full revolution (360 deg, per revolution)
d. Adjust gas valves on the main burner.
e. Replace & secure knobs
23
Figure 83
CSA INTERNATIONAL
Project 2056658