Charmhigh-V1.0-2016 |
27
All Rights Reserved
number which mount next;
(3)
Comp. cnt.:
Show total mounted component count this run time;
(4)
Pcb cnt.:
Show total mounted PCB count;
(5)
Ave. speed:
Show average mount speed, unit is chip per hour;
(6)
Time cnt.:
run time of this time;
(7)
Tray start IC:
Click to set the start IC
‟s ID of IC tray; (below „Time cnt.‟Not viewing
where hasn‟t tray information in file)
(8)
Up camera:
The first button in the left bottom of screen, click to show image of up
camera;
(9)
Work light:
The second button in the left bottom of screen, click to switch work
light;
(10)
PCB calibration:
The third button in the left bottom of screen, click to calibrate
PCB directly;
(11)
Vacuum detection:
The fourth button in the left bottom of screen, click to open or
close vacuum detection, note, if close vacuum detection here, machine will not
detect lack of material, also will not discard material due to vacuum insufficient;
(12)
Mount head homing:
The fifth button in the left bottom of screen, click to move
mount head to the farthest location to origin;
(13)
Step:
I.e. mount as step by step, in order to test;
(14)
Run:
Run normally;
(15)
Stop:
Stop mount.