15
PIC6-9
(1)
First IC center coord. X/Y:
on the left-down side corner;
(2)
Last IC center coord. X/Y:
on the right-up side corner
;
(3)
X/Y direction number
: The number of X/Y direction on IC
(4)
Start IC number
: from number 0, IC number from left to right, up to down, when
running, machine will start from your selected IC number.
6.1.4. Panel edit
Batch is very convenient for same multi PCBs, before mounting, machine need to
know the position of each PCB, 2 ways of Batch:
Coord. or Array
positioning for PCB.
Coord. positioning according to the origin point of each PCB, coord. way is complicated
but more accurate; Array positioning need to know Line, the number of columns and
spacing, then machine will calculate the origin point automatically.
6.1.4.1. Coord.
Coordinate way image as below: