background image

Operating

and

Installation Instructions

CHARNWOOD

Country 8 MkII and Country 12 MkII

Flat Top, Low Canopy & High Canopy

Multifuel Roomheaters

Bishops Way, Newport, Isle of Wight, PO30 5WS, U.K.

Tel: (01983) 537799

Fax: (01983) 537788

E-Mail: charnwood@ajwells.co.uk

Summary of Contents for Country 12 Mk2

Page 1: ...on Instructions CHARNWOOD Country 8 MkII and Country 12 MkII Flat Top Low Canopy High Canopy Multifuel Roomheaters Bishops Way Newport Isle of Wight PO30 5WS U K Tel 01983 537799 Fax 01983 537788 E Mail charnwood ajwells co uk ...

Page 2: ... Trouble Shooting 6 Installation Instructions Health Safety Precautions 7 Performance 7 Chimney 7 Hearth and Fire Surround 7 Hot Water System 7 Fitting The Optional Add In Boiler 8 Connections To Flues 8 Soot Doors 9 Pre Lighting Check 9 Commissioning 9 Overall Dimensions Country 8 10 Overall Dimensions Country 12 11 CHARNWOOD COUNTRY 8 Mk II COUNTRY 12 Mk II Operating and Installation Instruction...

Page 3: ...son in a well ventilated dry place for at least one year but preferably two years before use Peat Ensure that the peat is well dried before use Burning wet peat will give rise to heavy tar deposits and reduced outputs PETROLEUM COKE IS NOT SUITABLE FOR USE ON THIS APPLIANCE ITS USE WILL INVALIDATE THE GUARANTEE At first you may find it helpful to try several fuels to find the most suitable If you ...

Page 4: ...ning wood or peat ash should be allowed to build up and generally weekly riddling will be sufficient The fire should be riddled with the doors shut see Fig 2 Place the tool onto the riddling lever and rotate between the 1 o clock and 3 o clock positions several times Too much riddling can result in emptying unburnt fuel into the ashpan and should therefore be avoided If any clinker forms it should...

Page 5: ...t use abrasive cleaners or pads as these can scratch the surface which will weaken the glass and cause premature failure Aerosol spray cleaners should not be used near the appliance whilst it is under fire When not in use If the fire is going to be out of use for a long period for instance in the summer then to prevent condensa tion and hence corrosion the thermostat should be left at the maximum ...

Page 6: ...hanging the front firebars will cause the glass to blacken It is always more difficult to keep the glass clean when running the stove very slowly for long periods If blackening of the glass still occurs check that the top of the stove is bolted on securely and that the seal between the top and the body is intact Also check that all flue connections and the blanking plate are well sealed It is also...

Page 7: ...sought regarding the necessity of having the chimney lined If it is found necessary to line the chimney then a lining suitable for Solid Fuel must be used If there is no existing chimney then a prefabricated block chimney or a twin walled insulated stainless steel flue to BS 4543 can be used either internally or externally These chimneys must be fitted in accordance with the manufacturers instruct...

Page 8: ...hers over the tappings on the outside of the appliance and fit the backnuts ensuring that the boiler is held tightly against the rear inside face of the appliance and that the top edge of the boiler is level or runs uphill to the flow tapping Gaps between the boiler and the firebricks should be filled with fire cement Replace the back fireplate the side fireplates and the front firebar On the Coun...

Page 9: ...ust all be fitted and should move freely and easily when the riddling mechanism is operated 2 The plates round the sides and back of the grate must be in position and sitting correctly 3 The throat plate must be fitted in the roof of the appliance and should be checked to ensure that it has not become dislodged in transit The method of location and positioning of the throat plate is shown in fig 3...

Page 10: ...High Canopy Country 8 LC Low Canopy Country 8 FT Flat Top 552 508 381 1012 526 526 526 381 752 552 513 322 513 381 513 513 322 513 322 639 513 460 1072 106 587 812 126 699 587 587 46 469 46 461 125 Country 8 MkII Dimensions All dimensions are in mm Page 10 TW16 3 99 ...

Page 11: ...0 180 210 180 210 655 1098 320 462 386 518 1158 584 106 45 655 793 320 Ø154 462 386 518 853 584 125 489 45 658 595 320 Ø154 462 386 518 718 584 125 468 45 Ø154 616 480 Country 12 HC High Canopy Country 12 LC Low Canopy Country 12 FT Flat Top Page 11 TW16 3 99 ...

Reviews: