Fig.7. Vertical register plate with bricked up fireplace
Fig. 8. Horizontal register plate with rear flue connection
Fig. 9. Horizontal register plate with top flue connection
Fig. 10. Horizontal register plate with optional vertical rear flue connector
Rod through the hole in the front of the stand. Now move the stove
towards you to align the slots in the side of the stand with the 6mm
tapped holes in the base brackets. Fix in position with the bolts that
were used to secure the cover and replace the Air Control Knob.
PRE LIGHTING CHECK
Before initial lighting the following points should be checked:
1. The bottom grate bars must all be fitted and should move freely
and easily when the riddling mechanism is operated.
2. The plates round the sides and back of the grate must be in
position and sitting correctly.
3. The throat plate must be fitted in the roof of the appliance and
should be checked to ensure that it has not become dislodged in
transit. The method of location and positioning of the throat plate is
shown in Fig. 4.
COMMISSIONING
On completion of the installation and after allowing a suitable period
of time for the fire cement and mortar to dry out, the stove should
be lit and checked to ensure that smoke and fumes are taken from
the appliance up the chimney and emitted safely. Also check all joints
and seals. On completion of the installation and commissioning please
leave the operating instructions with the customer and advise them
on the use of the appliance.
Alternative
Soot Door
Positions
Register Plate
With Soot Door
Alternative
Soot Door
Positions
Register Plate
With Soot Door
Alternative
Soot Door
Positions
Register Plate
With Soot Door
Register Plate
Soot Door
in side or rear
of Chimney
11
®
INSTALLATION INSTRUCTIONS
charnwood