Item Part No.

Description

1*

008/SY16S

Door Seal Set Inc.Adhesive

31

004/PY25B

Hinge Post Shim 0.9mm

2*

008/FW29

Door Seal Adhesive

32

004/PY25A

Hinge Post Shim 2mm

3

002/CG01

Bottom Grate Bar

33

008/AY37

Air Control Knob

4

002/CG01S5 Set of Grate Bars(5)

34#

002/SY01/A Door Assembly

5

002/SY15 

Side Fire Plate

35

004/SY21

Air Bypass Slide

6

002/HW16

Back Fire Plate

37

002/CG11

Driving Rod

8

006/SY18

Glass (Inc Seal)

38

010/JS20

Air Supply Box

9*

008/SY43

Glass Seal

39

004/JS32

Air Control Rod

10

004/KV23

Glass Retainer

40

004/JS21

Primary Air Slide

11

011/JS29S

Set of Fire Bricks (4)

41

008/SY13

Upper Quattro Box Gasket

12

004/XV30

Brick Retainer

42

008/JS15

PTFE Slide

13

010/JS31

Throat Plate

44

010/JS14

Slide Spacer Plate

15

012/SY33

Mover Bar

45

001/JS10

Firebox (Cove1SR)

16

002/SY30

Carrier Bar

46

012/PV09

Blanking Plate

17

012/CG05

Idler Rod

47

010/EY51

Clamping Plate

18

002/CG12

Driving Gratebar

48

002/PV12B

Flue Collar

19

004/SY17

Ashpan

49

010/EY19

Flue Spacer Ring

20

002/SY07

Front Firebar

50#

010/SY11

Base Cover

21

002/SY08

Deepening Bar

51

010/PV33

Vert. Rear Flue Adapter (Opt'l Extra)

22

002/RY15

Door Knob & Spindle

52#

010/SY02

Store Stand

23

008/FFN001 M12 Half Nut

54#

010/SY12

Centre Stand

24

004/ST008

Tabbed Locking Washer

55

002/AY27

Riddler Knob

25

002/AY14

Door Catch

56

012/JS25

Serial No. Label

26

010/ST031

Door Catch Spacer

57

008/FFS068

Levelling Screw - M8 x 10mm Grub Screw

27

008/FFW015 M12 Double Coil Spring Washer

58

008/FFM039 Decorative Cap

28

008/PY13

Door/Riddling/Ashpan Tool

59

010/PY38

Door Catch Stop

29

008/BW39/S Hinge Pin Set

60*

010/EW51

Ash Carrier (Optional Extra)

30

002/PY24

Hinge Post

61*

010/JS52

External Air Manifold Kit

Item Part No.

Description

To obtain spare parts please contact your local stockist giving Model, Part No. and 

Description. In case of difficulty contact the manufacturer at the address shown.

This drawing is for identification purposes only.

Summary of Contents for Cove 1SR

Page 1: ...Operating Installation Instructions charnwood ...

Page 2: ......

Page 3: ...Trouble Shooting 7 If You Need Further Help 8 INSTALLATION INSTRUCTIONS Health Safety Precautions 9 Specification 9 Chimney 9 Hearth Fire Surround 9 Connection to Flues 10 Soot Doors 10 Unpacking The Stove 10 Pre Lighting Check 11 Commissioning 11 Dimensions 12 Parts Lists 13 Certification 14 Lighting 5 Controlling The Fire Fitting The Stove To Its Stand 10 Ref COVE1SR 06 13 Issue E ...

Page 4: ...ng the stove in situations where children aged and or infirm persons are present a fireguard must be used to prevent accidental contact with the stove The fireguard should be manufactured in accordance with BS 8423 2002 Before lighting the stove check with the installer that the work and checks described in the Installation Instructions have been carried out correctly and that the chimney has been...

Page 5: ...THE FIRE The fire is controlled by the single air control knob shown in Fig 1 Pull the knob out to make the fire burn faster push it in to make the fire burn slower The air control provides carefully balanced air to enable optimum burning conditions without the need to adjust multiple controls If for any reason the flame dies whilst there is fresh fuel in the stove then the door must be cracked op...

Page 6: ...mature failure Aerosol spray cleaners should not be used near the appliance whilst it is under fire When Not in Use If the fire is going to be out of use for a long period for instance in the summer then to prevent condensation and hence corrosion the air control should be left fully open and the fire door left ajar It is also advisable to sweep the chimney and clean out the fire Spraying the insi...

Page 7: ...itted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire 25Pa following points should be noted and with a little care should enable the glass to be kept clean in most situations a The airwash relies on a supply of heated air to keep the glass c...

Page 8: ...es occur push the air control in fully and tightly close the door of the appliance This should cause the chimney fire to go out in which case the control should be kept closed until the stove has gone out The chimney and flueways should then be cleaned If the chimney fire does not go out when the above action is taken then the fire brigade should be called immediately After a chimney fire the chim...

Page 9: ...e to the top of the chimney The minimum internal chimney size is 125mm diameter 5 inches or 125mm x 125mm These stoves are NOT to be used in a shared flue If an existing chimney is to be used it must be swept and checked it must be in good condition free from cracks and blockages and should not have an excessive cross sectional area If you find that the chimney is in poor condition then expert adv...

Page 10: ... most back outlet installations it will be necessary to have a soot door to enable the chimney to be swept This may either be in the actual brickwork of the chimney or in the register plate Various types and positions of soot doors are shown in figures 7 to 10 UNPACKING THE STOVE The stove arrives bolted and shrink wrapped to its pallet The wrapping is first removed then the stove released from th...

Page 11: ...n position and sitting correctly 3 The throat plate must be fitted in the roof of the appliance and should be checked to ensure that it has not become dislodged in transit The method of location and positioning of the throat plate is shown in Fig 4 COMMISSIONING On completion of the installation and after allowing a suitable period of time for the fire cement and mortar to dry out the stove should...

Page 12: ...E VIEW BACK VIEW CENTRE LOW STAND STAND STORE STAND 399 352 82 129 129 636 TOP VIEW 795 745 423 383 302 347 136 636 223 795745 423 98 199 103 437 596 546 103 Max dimension with door open 673 12 DIMENSIONS charnwood Flue Outlet to suit 125mm 5 Fluepipe ...

Page 13: ...Retainer 42 008 JS15 PTFE Slide 13 010 JS31 Throat Plate 44 010 JS14 Slide Spacer Plate 15 012 SY33 Mover Bar 45 001 JS10 Firebox Cove1SR 16 002 SY30 Carrier Bar 46 012 PV09 Blanking Plate 17 012 CG05 Idler Rod 47 010 EY51 Clamping Plate 18 002 CG12 Driving Gratebar 48 002 PV12B Flue Collar 19 004 SY17 Ashpan 49 010 EY19 Flue Spacer Ring 20 002 SY07 Front Firebar 50 010 SY11 Base Cover 21 002 SY08...

Page 14: ...on of co in combustion products Flue gas temperature Space heating thermal output Energy efficiency Fuel types A Division of A J Wells Sons Limited Registered in England No 03809371 10 Bishops Way Newport Isle of Wight PO30 5WS United Kingdom A J WELLS SONS LTD A J WELLS SONS LTD IS44 CPD 2010 550mm 550mm 0 20 248 C 4 0kW 79 3 Wood Logs ...