background image

Issue A

To obtain spare part s please contact your local stockist
giving Model, Part No. and Description. In case of difficulty
contact the manufacturer at the address shown.
This drawing is for identification purposes only.

* These items are not shown on the drawing.
# Please specify colour when ordering.”

DETAIL A

Enlarged Scale

52

54

45

51

46

47

48

49

50

13

11

7

5

18

6

21

20

28

22

44

30

29

19

42

39

33

35

36

37

38

34

15

4

17

3

40

41

56

31

8

10

55

16

23

24

25

26

27

Item

Part No.

Description

Item

Part No.

Description

1*

008/PY23S

Door Seal Set Inc.Adhesive

2*

008/FW29

Door Seal Adhesive

3

002/CG20

Bottom Grate Bar

4

002/CG20S10

Set of Grate Bars (10)

5

002/CY15

Side Fire Plate

6

002/AY16

Back Fire Plate

7

004/FS19

Ash Shedding Plate

8

006/PY18

Glass

9*

008/PY45

Glass Seal

10

004/KV23

Glass Retainer

11

011/FS09S

Set of Fire Bricks (2)

13

010/FS31

Throat Plate

15

012/AY33

Mover Bar

16

002/AY30

Carrier Bar

17

012/AY13

Idler Rod

18

012/AY15

Riddler Rod

19

004/PY17

Ashpan

20

002/AY07B

Front Firebar

21

002/FS08

Deepening Bar

22

002/PY11

Door Knob & Spindle

23

008/FN001

Spindle Nut

24

004/ST008

Tabbed Locking Washer

25

010/PY14

Door Catch

26

010/PY05

Door Catch Stop

27

008/FW015

Door Spring

28

008/PY13

Door/Riddling/Ashpan Tool

29

008/BW39/S

Hinge Pin Set (2 per set)

30

002/PY24

Hinge Post

31

004/PY25B

Hinge Post Shim 0.9mm

33

008/AY37

Air Control Knob

34

008/FV49

Thermostat Flap

35

008/FW48

Thermostat

36

004/CS18

Thermostat Connector Tube

37

004/FS16

Thermostat Extension Rod

38

008/BW50

Thermostat Knob

39

004/PY32

Air Control Rod

40

004/FS21

Secondary Air Slide

41

008/DS12

Thermostat Box Gasket

42

010/FS20

Thermostat Box

44

002/PY01

Door

45

001/FS10

Firebox (Cove2B)

46

012/TW09

Blanking Plate

47

010/AY51

Clamping Plate

48

002/CH12B

Flue Collar

49

010/NV11

Flue Spacer Ring

50

010/PY36

Base Cover

51

010/TW33

Vert. Rear Flue Connector (Opt'l Extra)

52

010/PY33/##

Store Stand

54

010/PY34/##

Centre Stand

55

002/AY27

Riddler Knob

56

012/FS11

Serial No. Label

®

charnwood

BISHOPS   WAY,   NEWPORT,   ISLE   OF   WIGHT     PO30   5WS,   UNITED   KINGDOM

T:+ 4 4 (0 )19 8 3 5 377 9 9

F :+ 4 4 (0 )19 8 3 5 377 8 8

SPA RE S@C H A RN WO O D .C O M

WWW.C H A RN WO O D .C O M

®

charnwood

COVE 2B PARTS LIST

16

Summary of Contents for Cove 2B

Page 1: ... Operating Installation Instructions charnwood ...

Page 2: ......

Page 3: ...ing Trouble Shooting If You Need Further Help Health Safety Precautions Specification Chimney Hearth Fire Surround Central Heating System System Controls Connection to Flues Soot Doors Unpacking The Stove Pre Lighting Check Commissioning Dimensions Parts Lists Certification 4 4 4 5 5 5 5 6 6 6 6 7 7 7 9 10 10 10 10 11 12 12 12 12 13 13 15 16 17 INSTALLATION INSTRUCTIONS Lighting 5 Controlling The ...

Page 4: ...e manufactured in accordance with BS 8423 2002 Do not use an aerosol spray on or near the stove when it is alight There is a risk of explosion or flash ignition of the spray This stove is capable of intermittent or continuous operation Please pay careful attention to the special points made with each type of fuel as they will help you to get the best from your stove It must be remembered that only...

Page 5: ...he stove riddle slightly and then empty the ashpan When burning wood ash should be allowed to build up and only riddled when the ash begins to cover the slots in the rear fireplate The fire should be riddled with the door shut see Fig 2 Place the tool onto the riddling lever and rotate between the 1 o clock and 3 o clock positions several times Too much riddling can result in emptying unburnt fuel...

Page 6: ... fire is burning brightly before filling with fuel When the new fuel has ignited the thermostat control should be turned down to the required setting If the central heating pump is off overnight then the thermostat may be left at the same setting for both day and night operation If the central heating pump is on overnight then set the thermostat control to give the required level of heating Some e...

Page 7: ...down from its back supports Lift up from the back supports and rotate to remove through the doorway see Fig 4 The chimney should be swept at least twice a year Where a top outlet is used it will generally be possible to sweep the chimney through the appliance If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which ...

Page 8: ...balancing the pump may be pumping the water too quickly around the system or the radiators may need bleeding Please ask your installer to check Freezing Door Glass Blacks Up Keeping the glass clean requires a certain amount of experimentation due to the differences in the draw of different chimneys The following points should be noted and with a little care should enable the glass to be kept clean...

Page 9: ...e action is taken then the fire brigade should be called immediately After a chimney fire the chimney should be carefully examined for any damage Expert advice should be sought if necessary If you need further help with your Charnwood Cove then your Installer will be able to provide the answers to most questions Your Local Charnwood Premier Dealer has a great deal of experience and will also be ab...

Page 10: ...e chimney then a lining suitable for Solid Fuel must be used If there is no existing chimney then a prefabricated block chimney or a twin walled insulated stainless steel flue to with BS EN 15287 1 2007 can be used either internally or externally These chimneys must be fitted in accordance with the manufacturers instructions and Building Regulations Anki pumice liners or chimney blocks will give a...

Page 11: ...own in Figs 6 and 7 The height differential between the header tank and the appliance must not exceed 15 2 metres 50 feet If all four boiler tappings are used then if possible diagonal pairs should be connected for domestic hot water and central heating Where a common return is used an injector tee must be incorporated into the system as shown in Fig 8 This will ensure that a good domestic hot wat...

Page 12: ...Fig 12 is used then the chimney may be swept through the appliance Horizontal lengths of flue must be kept to a minimum and should not be more than 150mm 6 inches long The sealing face of the flue collar should be coated with fire cement before fixing to the body of the stove using the two screws provided The blanking plate must be removed sealed with fire cement and refitted care being taken to e...

Page 13: ...olts and 4 plain washers A 13mm open ended spanner is required Replace the cover side bolts and Air Control Knob 2 Store stand PRE LIGHTING CHECK COMMISSIONING Place the Store Stand on the hearth with at least 100mm clear space behind it Remove the lower cover as described above it is not used With 2 people carefully lift the stove on to the stand such that the front end of the Air Control Rod is ...

Page 14: ...smoke and fumes are taken from the appliance up the chimney and emitted safely Also check all joints and seals On completion of the installation and commissioning please leave the operating instructions with the customer and advise them on the use of the appliance charnwood INSTALLATION INSTRUCTIONS 14 ...

Page 15: ...80 394 104 CENTRE LOW STAND STAND STORE STAND Back View 578 341 626 Front View 698 753 Side View 824 587 872 944 999 300 124 247 104 27 824 587 872 394 80 944 999 554 520 153 350 402 88 145 153 456 399 charnwood FLUE OUTLET TO SUIT 150MM 6 0 FLUE PIPE 15 ...

Page 16: ... 20 002 AY07B Front Firebar 21 002 FS08 Deepening Bar 22 002 PY11 Door Knob Spindle 23 008 FN001 Spindle Nut 24 004 ST008 Tabbed Locking Washer 25 010 PY14 Door Catch 26 010 PY05 Door Catch Stop 27 008 FW015 Door Spring 28 008 PY13 Door Riddling Ashpan Tool 29 008 BW39 S Hinge Pin Set 2 per set 30 002 PY24 Hinge Post 31 004 PY25B Hinge Post Shim 0 9mm 33 008 AY37 Air Control Knob 34 008 FV49 Therm...

Page 17: ...EC Certificate of Conformity no FS44 CPD 2009 100mm 0 68 0 21 315 C 353 4 6kW 7 1kW 6 4kW 9 3kW 74 6 76 5 WoodLogs Solid Mineral Fuel Wood Logs Solid Mineral Fuel Wood Logs Solid Mineral Fuel Wood Logs Solid Mineral Fuel Wood Logs Solid Mineral Fuel Wood Logs Solid Mineral Fuel C A Division of A J Wells Sons Limited Registered in England No 03809371 A J W E L L S S O N S L T D Bishops Way Newport ...

Page 18: ...e d R e g i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM T 44 0 1983 537777 F 44 0 1983 537788 CHARNWOOD AJWELLS CO UK WWW CHARNWOOD COM y o u r p re m i e r d e a l e r Ref 2B 05 10 ...

Reviews: