background image

Notes to the Installation Engineer: Please make sure the
customer is familiar with the initial lighting and operating
procedures before leaving the site and that this instruction
booklet is left with them when the final commissioning is
complete.

Please check that the following components are included
before you start on the assembly.

The following stove components are delivered in 2 boxes:

Box 1: 1 Stove Body inc. baffle and flue diverter.

Box 2: 1 Burner Unit and coal set.

Assembly

IMPORTANT: ENSURE THAT THE CONCEALED
DOOR LOCK IS REMOVED BEFORE ATTEMPTING
TO OPEN THE GLASS DOOR USING THE HANDLE .

* Remove spinwheel from the bottom centre of door.

* Remove the lower bolt, using a 13mm spanner or socket,
and retain.

* Open door using handle and remove contents packed
inside stove, including front fire bar, noting location for
reassembly.

* Fit draught diverter to rear of stove using nuts and bolts
provided.

* Fit baffle plate by locating on the 4 lugs inside body with
the curved edge towards the front of body curving upwards
as shown in Fig. 2.

* Insert burner through door aperture with valve on right
hand side.

* Manoeuvre burner and locate so that rear lugs fit over
rear base plate: front lugs sitting on front of base plate and
secure with two bolts through top of base plate, the gas
valve will then be neatly located through cut out in right
hand side of stove body.

Flue Spillage Monitoring System.

Charnwood Grosvenor stoves are fitted with an oxygen
depletion sensitive pilot.

Location And Recommended Hearth

And Fire Opening Specification.

The location of Charnwood Grosvenor model stoves
should have the following space around them:

The hearth should protrude at least 150mm (6”) in front of
the stove body and be at least 12mm (1/2”) thick.

In most buildings with solid concrete floors this
requirement will have been met by the floor itself. There
should also be a gap of at least 150mm (6”) on either side
of the stove, more if possible as the greater the space the
greater the amount of heat being released into the room. If
the stove is to be fitted into an existing opening there
should be a minimum of 150mm (6”) clearance on both
sides, with the back of the flue diverter box 15mm clear of
the rear wall.

On all stove installations no combustible material should
cover the hearth, or be placed any closer then 225mm (9”)
from the stove. This includes carpeting and other
combustible floor coverings.

Connection To The Chimney.

Use 125mm dia. flue pipe to make the chimney connection.
If required, 100mm dia flue pipe may be used.

Before you install the stove make sure the chimney flue
outlet is correctly positioned to align with the flue outlet on

Charnwood Grosvenor

Installation Instructions

Baffle Plate

Fig. 2. Baffle Plate

Page 6

SV 2/00

Summary of Contents for Grosvenor

Page 1: ...Operating and Installation Instructions CHARNWOOD GROSVENOR Bishops Way Newport Isle Of Wight PO3O 5WS U K Tel 01983 537799 Fax 01983 5377887 ...

Page 2: ...flue outlet must be correctly positioned to align with the flue outlet on the stove that you have bought Connection to the chimney the job of the installation engineer is detailed in Section 1 The stove must not be used with the door open Safety Reminders Charnwood stoves are efficient appliances giving off convected conducted and radiated heat All the surfaces of the stove except the controls are...

Page 3: ... tripping have the flue and chimney checked by your installation engineer Lighting and controlling the stove Remember that the stove is designed to be operated with the door and spinwheel securely closed 1 Near the stove will be the gas isolation tap Turn this to the on position 2 Between the front and rear legs on the right hand side of the stove you will find the burner control knob as shown in ...

Page 4: ...h a suitable glass cleaner available from your stove supplier To The Customer PLEASE READ THE FOLLOWING PROCEDURES AND SERVICE CHECKS BUT PLEASE NOTE THEY MUST ALL BE CARRIED OUT BY A QUALIFIED INSTALLA TION ENGINEER IF THE DOOR GLASS BECOMES DAMAGED OR BROKEN DO NOT USE THE STOVE Glass Replacement 1 Before carrying out the glass replacement we suggest that for safety reasons the gas supply is tur...

Page 5: ...m dust or dirt 4 Finally ensure that the thermocouple a very delicate electro mechanical device has not become damaged in any way If it is damaged a replacement pilot assembly should be obtained and fitted by your installation engineer FINAL REMINDERS We remind you that it is a legal requirement that the stove is installed by a qualified and accredited installation engineer Improper installation a...

Page 6: ...e plate the gas valve will then be neatly located through cut out in right hand side of stove body Flue Spillage Monitoring System Charnwood Grosvenor stoves are fitted with an oxygen depletion sensitive pilot Location And Recommended Hearth And Fire Opening Specification The location of Charnwood Grosvenor model stoves should have the following space around them The hearth should protrude at leas...

Page 7: ...tion The gas supply must be properly sized to provide the correct gas rate at running pressure when measured at the inlet valve The final connection to the stove must be made with a suitable 8mm dia gas pipe It is essential that a gas isolation tap is provided upstream of the stove in a position that is easily accessible Gas Pressure Make sure that there is adequate gas pressure and volume to the ...

Page 8: ...ural Gas 1st Layer below shown dotted 11 12 13 14 15 16 17 18 19 20 21 L L L L L L L L L L L ø8 0 Holes Air Tunnel Air Tunnel 1 2 3 4 5 6 7 8 9 10 Fig 3 Coal Layer 1 Natural Gas Air Tunnel S S S S S L L L L L Page 8 SV 2 00 ...

Page 9: ...s 2 3 LPG 16 17 18 19 20 21 22 23 24 25 26 1st Layer below shown dotted 3rd Layer L L L L L L L L S S S ø8 0 Holes 1 2 3 4 5 10 6 13 15 7 8 9 11 12 14 Fig 5 Coal Layer 1 LPG S S S S S L L L L L L L L L L Page 9 SV 2 00 ...

Reviews: