16
Air sealed in hydraulic system while
operating
Loosen bleed screw by some
rotations before operating the log
splitter
Bleed screw is not tightened before
moving the log splitter
Tight the bleed screw up before
moving the log splitter
Oil drain bolt with dipstick is not tight.
Tighten the oil drain bolt with
dipstick
Oil leaks
around
cylinder ram or
from other
points
Hydraulic control valve assembly and/or
seal(s) worn.
Contact the dealer
EXPLODED VIEW