Troubleshooting
Use the following troubleshooting table as a guideline to diagnose your Orca system should problems develop This table
cannot replace the knowledge that an experienced operator or cryogenic technician has, and should be considered as a guide
only. The table consists of the Symptom, Probable Cause and Remedy columns. Probable causes for a specific problem are
listed in a descending order of significance. That is, check out the first cause listed before proceeding to the next. The error
codes reference the Flowcom
®
Flow Meter System Installation and Service Manual
Symptom
Probable Cause
Remedy
No Flowcom or worklight power
Breaker tripped in 12 volt control circuit.
12 volt circuit open.
Truck key in OFF position
Allow breaker to reset or replace
breaker in junction box. Verify current
draw is less than breaker rating.
Verify connector is plugged in at front of
tank. Also inspect wires from connector
to control panel for break, cuts, etc.
Repair if necessary.
Turn to ACC or ON
Unstable flow of product.
Depletion of subcool.
Vessel transmitter fault.
Manual valves closed.
Liquid level low.
Two-phase flow. This occurs when a
combination of liquid and gas flows
through the pump.
Add subcool by opening pressure
building coil.
Ensure all valves are open.
Check liquid level gauge. Pump delivery
of product should not be attempted at
low liquid levels.
Caution! Serious damage
to pump can
occur if pump is
run dry!
Increase subcool. If the saturation
pressure is high, the vessel may have
to be blown down, then subcool added.
Paper out. (Print/Exit)
Add paper, check cables
Verify that the cables to the printer are
plugged in, that the printer is turned on
and that there is paper in the printer.
Flowcom parameters cannot be
changed.
Improper Flowcom password entered.
Factory passwords are set to 1000 for
the Flowcom 1000 and 3000 for the
Flowcom 3000
Customers are expected to change
the passwords for the three levels of
security as they see fit. Refer to the
Flowcom manual for more information.
Do NOT forget what the password is
changed to.
Summary of Contents for Orca MicroBulk CO2 Series
Page 2: ......
Page 13: ...Safety 7 Product Manual Orca CO2 Series MicroBulk Delivery System...
Page 14: ...8 Safety Product Manual Orca CO2 Series MicroBulk Delivery System...
Page 28: ...22 Operations Product Manual Orca CO2 Series MicroBulk Delivery System...
Page 42: ...36 Components Systems Product Manual Orca CO2 Series MicroBulk Delivery System...
Page 48: ...42 Troubleshooting Product Manual Orca CO2 Series MicroBulk Delivery System...
Page 54: ...48 Specifications Product Manual Orca CO2 Series MicroBulk Delivery System Piping Schematic...
Page 55: ...49 Specifications Product Manual Orca CO2 Series MicroBulk Delivery System Nomenclature...
Page 62: ...Product Manual Orca CO2 Series MicroBulk Delivery System...