background image

User Manual

Summary of Contents for F4XIP

Page 1: ...User Manual ...

Page 2: ...ten consent from Chauvet Document Printing For best results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure the printer to scale the content accordingly Intended Audience Any person installing operating and or maintaining this product should completely read through the guide that shipped with the product as well as this manual bef...

Page 3: ...tion 5 Product Dimensions 6 3 Setup 7 AC Power 7 AC Plug 7 Power Linking 7 4 Mounting 8 Orientation 8 Mounting Points 8 DRB F50CM Dual Function Rig Bar Dimensions 9 DRB F100CM Dual Function Rig Bar Dimensions 9 Mounting with Dual Function Rig Bar Hanging 10 Truss Installation 11 Mounting with Dual Function Rig Bar Stacking 12 Removing the Feet 12 Flat Wall Installation 13 Mounting Points on a Flat...

Page 4: ...B Modules 22 Calibration Recall 22 F4XIP LED Module Removal 23 LED Module Thumbscrews 23 Removing a Module from the Front 24 Removing a Module from the Rear 26 Removing and Replacing the LED Masks 27 8 F4XIP Serviceability 28 9 Typical F4XIP Installation Hanging 30 10 Operation 31 Additional Hardware and Software 31 About NovaLCT and SmartLCT 31 Description 31 Receiver Card Configuration Files 31 ...

Page 5: ... 7 days of delivery Text Conventions Symbols 4 F4XIP products 1 Road case 1 Seetronic Powerkon IP65 power cable 4 Seetronic Powerkon IP65 power linking cables 4 Seetronic Etherkon IP65 signal linking cables 5 spare LED masks Front service tool Quick Reference Guide Convention Meaning 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modi...

Page 6: ...Make sure the power cable is not crimped or damaged Always make sure the product is being connected to the proper voltage in accordance with the specifications in this manual or on the product s specification label To eliminate unnecessary wear and improve its lifespan during periods of non use completely disconnect the product from power via breaker or by unplugging it Never connect this product ...

Page 7: ...frame design allows for overhead hanging ground stacking and wall mounting maximizing installation flexibility and aftermarket front and rear service simply push out modules from the rear using the handles or use the included service tool from the front Front LED surface protective design features prevent damage when handling 4x stainless steel standing feet to keep the LEDs from touching the floo...

Page 8: ...ons Threaded Mounting Hole Size M12 x6 Test Button Power Signal Indicator LEDs Male Speego Connections Alignment Magnets x4 Alignment Magnets x4 Seetronic Powerkon In IP65 covers not shown Seetronic Powerkon Out IP65 covers not shown Seetronic Etherkon Signal Through Ports IP65 covers not shown Alignment Magnets x4 Alignment Conicals Alignment Bolts x4 ...

Page 9: ...P Pixels per Panel 104 x 208 Total Pixels per Panel 21 632 Pixels per LED Module 52 x 104 Total Pixels per LED Module 5 408 LED Module Dimensions 250 x 500 mm To calculate the number of panels horizontally and vertically supported by a single VIP Drive 10 5 Nova or VIP Drive 83R Nova you will use The number of pixels per panel The screen resolution you would like to use for your video wall display...

Page 10: ...duction F4XIP User Manual Rev 1 Product Dimensions 37 17 in 944 mm 18 66 in 474 mm 17 48 in 444 mm 39 37 in 1000 mm 14 21 in 361 mm 5 mm 5 8 mm 4 mm 19 68 in 500 mm 10 mm 12 mm 2 46 in 62 55 mm 3 25 in 82 5 mm ...

Page 11: ... Linking All F4XIP panels support power linking Refer to the following table for specifications Always connect the product to a protected circuit a circuit breaker or fuse Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire To eliminate unnecessary wear and improve its lifespan during periods of non use completely disconnect the product from power ...

Page 12: ...with adequate space for ventilation configuration and maintenance Chauvet recommends following the general guidelines below When selecting an installation location consider ease of access for operation and routine maintenance Make sure to hang away from any flammable material as indicated in the Safety Notes section Never mount in places where rain extreme temperature changes or restricted ventila...

Page 13: ...nsions DRB F100CM Dual Function Rig Bar Dimensions 19 67 in 499 8 mm 19 98 in 507 6 mm 4 72 in 120 mm 2 36 in 60 mm 5 2 in 132 mm 6 65 in 169 mm Sold Separately 39 35 in 999 6 mm 39 55 in 1 007 4 mm 4 72 in 120 mm 2 36 in 60 mm 5 2 in 132 mm 6 65 in 169 mm Sold Separately ...

Page 14: ...g Bar from the F4XIP reverse the previous steps Tilt the panels away from each other to safely release the magnetic attachments When mounting a video panel assembly together mount the entire top row of panels using only the spring knobs before moving on to step 5 The alignment magnets on the F4XIP and Dual Function Rig Bar are designed to temporarily hold the weight of the panel to allow the user ...

Page 15: ... DRB F50CM or F100CM sold separately All applicable local codes and regulations apply to proper installation of this product WARNING The alignment magnets on the Dual Function Rig Bars are not designed for load bearing All Rig Bars in a panel assembly must be mounted individually to the mounting point Adjacent Rig Bars will NOT support the attached weight WARNING This product should only be used b...

Page 16: ...nt bolts from the F4XIP twist them counter clockwise with a 5 mm wrench until they come loose Warning The magnetic attachments are not load bearing and are intended for alignment assistance only Do not release panel until the hanging hardware has been fully secured Removing the feet may result in damage not covered by the warranty Alignment Conical x2 MaleSpeego Connection Female Speego Connection...

Page 17: ...tended for hanging or suspending from a truss or other overhead structure The 2 rear mounting holes in the middle of the product are intended for use with the Ground Support 2 Kit from Chauvet Spacers greater than 5 mm thick must be used at each mounting point between the panels and the struts The illustrations above are examples only Please refer to all applicable local codes and regulations for ...

Page 18: ...v 1 Spacers Flat Wall Installation When mounting to a flat wall spacers greater than 5 mm thick must be used at each mounting point between the panels and the struts as in the diagram below Steel Strut Spacer 5 mm M10 Bolt LED Module ...

Page 19: ... Each F4XIP can be easily joined vertically to a truss using an optional rig bar and the 2 female Speego connections located at the top corners of each panel Use the male Speego connections at the bottom of each panel to connect additional panels These connectors stay recessed when not being used Male Speego Spring Knob Tightening Latch Locking Bar ...

Page 20: ...h male Speego connections into female Speego connections 3 Turn the spring knobs clockwise until secure 4 Turn the tightening latches counter clockwise until secure Due to tolerances in the materials as well as wear and tear of the latches some tightening latches may not line up when tightened This is normal Warning The magnetic attachments are not load bearing and are intended for alignment assis...

Page 21: ...ng instructions to join panels horizontally 1 Align each of the panels male Speego connections with the corresponding female connections on the panels being added 2 Push male Speego connections into female Speego connections 3 Turn the spring knobs clockwise until secure 4 Turn the tightening latches counter clockwise until secure Due to tolerances in the materials as well as wear and tear of the ...

Page 22: ...cator light blinks green quickly When the LED blinks green slowly there is no signal Using the F4XIP Test Button Each F4XIP has a Test button used to ensure all LEDs are functional Use the Test button on each panel to perform a self test If self testing you must perform the test individually for each F4XIP You do not need to connect to a signal or use software To use the Test button you must conne...

Page 23: ...Ds 1 080 Blank rows of LEDs 168 Using this panel configuration with this input resolution may cause distortion To compensate for this restraint lower the refresh rate Doing this can make it possible for a height of up to 10 F4XIP panels at 30 Hz depending on the resolution width and height The menu path for these settings is Input Settings Custom Resolution Select from Width H Height V or Custom R...

Page 24: ...ust be within the limits of the port 30 or less Connecting panels to a single port in an arrangement which creates a rectangle larger than 30 panels will cause errors and problems even if only 30 panels are actually connected to that port Of the following examples only those where both of the following are true can work The number of panels connected to each port is equal to or less than 30 The pa...

Page 25: ...connected Connect power between the panels using the same procedure as the signal only using the Power Input and Power Output connectors You must adhere to the power linking specifications for each F4XIP model Refer to the Power Linking section for details on the number of panels that can be linked based on voltage from a single power connection Refer to the following diagrams for an example of po...

Page 26: ...tion Recall Each LED module for the F4XIP has individual calibration data for each LED permanently saved to the flash memory of the module The receiver card inside the control box or Service module of the F4XIP can use that data to ensure a uniformity of brightness across the entire panel To upload the calibration data from a new LED module to the Service Module of the panel follow the instruction...

Page 27: ...Replacement F4XIP LED Module Removal LED Module Thumbscrews Before an LED module can be removed from the F4XIP 2 thumbscrews must be loosened 1 Identify the module that needs to be removed 2 Loosen the 2 thumb screws securing the module to the frame ...

Page 28: ...XIP or F4XIPSQ use the included front service tool 1 Follow the instructions under LED Module Thumbscrews 2 Arrange the front service tool on the module to be removed so that each thumbscrew on the front service tool aligns with a threaded hole on the front of the module 3 Turn the thumbscrews to secure the front service tool to the module ...

Page 29: ...omes loose with it 5 Set the old module on a flat stable surface and remove the front service tool by loosening the thumbscrews until it comes free 6 Reverse the steps to install the replacement module Use caution when removing the module so as not to damage the connector attached to the back of the module WARNING The magnets on the modules are very powerful Keep fingers clear when installing ...

Page 30: ...teadily increasing force and keeping as straight as possible push the module forward away from the frame until it comes loose 4 Carefully tilt the module to pull it through to the rear or have someone on the other side take it 5 Reverse the steps to install the replacement module Use caution when removing the module so as not to damage the connector attached to the back of the module WARNING The m...

Page 31: ...he new LED mask in the space with the rear clips and arrows side facing in towards the product Ensure the orientation arrows point in the same direction as the arrows on the module 6 Push the mask in firmly until it is completely flush with the rest of the masks on the product A roller tool is recommended for this procedure 7 Secure in place with the 20 screws A dull plastic prying tool is recomme...

Page 32: ...iced from either the front of the panel or the rear of the panel at any time so panels can be serviced when access to either the front or the rear is restricted or impossible To access the F4XIP service module from the front of the panel 1 Remove the modules as described in LED Module Care and Replacement Service Module ...

Page 33: ...ed in the diagram below Use caution when removing these screws as the cover of the service module will be detached from the panel frame All components in the service module are attached to the cover Use caution when removing these screws as the cover of the service module will be detached from the panel frame All components in the service module are attached to the cover ...

Page 34: ...nal Step 3 Create a stable mounting surface e g truss or other stable surface for F4XIP mounting Step 4 Mount the first top row of the F4XIP products Refer to the Mounting section in this User Manual Step 5 Adjust the alignment of the first row using the Speego connectors latches Step 6 Connect the signal source to the VIP Drive 10 5 Nova or VIP Drive 83R Nova Step 7 Connect the VIP Drive to the S...

Page 35: ... data or mapping data panel layout Each of these are stored as separate files To load a new RCFGX file onto an F4XIP panel follow the steps under Updating RCFGX Files NovaLCT or Updating RCFGX Files SmartLCT Item Description VIP Drive 10 5 Nova or VIP Drive 83R Nova Interface between the signal source NovaLCT and the F4XIP being used NovaLCT and or SmartLCT Software applications used to design and...

Page 36: ...n the NovaLCT software 3 Click User U in the menu running across the top of the window to open the drop down menu 4 Click Advanced Synchronous System UserLogin A 5 Type admin into the password field and click the Login button on the screen or press the Enter key 6 Open Screen Configuration 7 Select the appropriate communications port for the connected panel assembly from the drop down list 8 Click...

Page 37: ...t in the mapping software To do this through NovaLCT 1 If the RCFGX files of the panels are up to date follow steps 1 9 under Updating RCFGX Files NovaLCT If the RCFGX files are not up to date follow steps 1 12 2 Click the Set Rotation hyperlink which appears in the upper right corner of the Cabinet Information section of the Receiving Card tab 3 Select either 90 or 270 to rotate the video within ...

Page 38: ... 4 Select the desired products of the same type from the products which are mapped 5 Right click on one of the selected products F6 Strip IP from Chauvet Professional shown for example purposes only If one product is selected Read back parameters can be selected which will download the RCFGX file from that product to the computer 6 Select Update receiving card parameters 7 Click the button to the ...

Page 39: ...id in the original box and with the original packing and accessories Chauvet will not issue call tags Call Chauvet and request a Return Merchandise Authorization RMA number before shipping the product Be prepared to provide the model number serial number and a brief description of the cause s for the return To submit a service request online go to www chauvetprofessional com service request Clearl...

Page 40: ...mensions Weight 19 69 x 2 56 x 39 37 in 500 x 65 x 1000 mm 30 lb 13 6 kg Transparency Housing Material Operating Temperature 0 Magnesium die cast 4 F to 104 F 20 C to 40 C Power Connection Data Connection Control Protocol Seetronic Powerkon IP65 Seetronic Etherkon IP65 Novastar Maximum Panels per VIP Drive 43Nova 2 Maximum Panels per VIP Drive 83R Nova Maximum Panels per VIP Drive 10 5 Nova 30 por...

Page 41: ...ill Road Industrial Estate Pinxton Nottingham UK Website www chauvetprofessional eu NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Benelux Address Stokstraat 18 Email BNLtech chauvetlighting eu 9770 Kruishoutem Belgium Website www chauvetprofessional eu Voice 32 9 388 93 97 France Address 3 Rue Ampère 91380 Chilly Mazarin Email FRtech chauvetlighting fr France Website www chauvetprofessional...