Page 15 of 27
onAir IP Panel 1 User Manual Rev. 2
Operation
IP Address
To set the IP address:
1. Go to the
Ethernet Setting
main level.
2. Select the
IP Address
option.
3. Select the first value of the IP address, from
2
,
10
, or
239
.
4. Press
<ENTER>
to cycle through the 4 values of the IP address.
5. Set the other 3 values from
000–255
.
6. Press
<MENU>
to exit when the IP address is set as desired.
Ethernet to DMX
When Ethernet to DMX is active, the selected universe of the Art-Net™ or sACN signal will be converted to
DMX and output through the 5-pin DMX out port.
1. Go to the
Ethernet Setting
main level.
2. Select the
Ethernet To DMX
option.
3. Select from
No
(do not convert) or
Yes
(convert).
Control Channel Assignments and Values
XYExtended(10)
XYBasic(6)
Channel Function
Value
Percent/Setting
1
Dimmer
000
255 0–100%
2
Fine dimmer
000
255 0–100%
3
X coordinate
000
255 0–100%
4
Fine X coordinate
000
255 0–100%
5
Y coordinate
000
255 0–100%
6
Fine Y coordinate
000
255 0–100%
7
Strobe
000
010 No function
011
255 Strobe, slow to fast
8
Effect macros
000
010 No function
011
039 Color chase
040
068 Police car
069
096 Firetruck
097
125 Fire
126
154 Clouds
155
182 Fireworks
183
211 Paparazzi
212
240 Lightning
241
255 No function
9
Effect macro speed
000
255 Speed, slow to fast
10
Control
000
255 See the
Channel Function
Value
Percent/Setting
1
Dimmer
000
255 0–100%
2
Fine dimmer
000
255 0–100%
3
X coordinate
000
255 0–100%
4
Fine X coordinate
000
255 0–100%
5
Y coordinate
000
255 0–100%
6
Fine Y coordinate
000
255 0–100%