Operation
COLORdash™ Accent Series User Manual Rev. 03c
-9-
Programming
It is possible to change the fixture’s various operation modes, DMX address, AUTO
programs, or STATIC settings while the fixture is on. Always make sure that you have
clear access to the DIP switches on the back of the fixture for easier fixture changes.
Starting Address
When any of the DMX modes is active as per the
Operation Modes Table
, you may
select the fixture’s starting DMX address (1~512) by setting DIP switches [1] through [9]
as per the table below.
Starting Address Settings
DIP Switch
1
2
3
4
5
6
7
8
9
Value
1
2
4
8
16
32
64
128
256
Procedure
1) Set DIP switches [10] through [12] to select a DMX operation mode, as per the
Operation Modes Table
.
2) Select the desired starting address (0 to 512) by setting DIP switches [1] through [9]
to ON or OFF until the sum of the value of the DIP switches in the ON position
matches the desired address number.
3) Refer to the examples below for more information.
Starting Address
Examples
These three examples are for STAGE 1 DMX mode. Therefore, in all three cases, DIP
switches [10], [11], and [12] are set to
OFF
.
a) To select DMX Address 1, set DIP switch [1] to
ON
.
b) To select DMX Address
64
, set DIP switch [7] to
ON
.
c) To select DMX Address
31
, set DIP switches [1], [2], [3], [4], and [5] to
ON
( 1+ 2 + 4 + 8 + 16 = 31).