background image

User Manual

Summary of Contents for COLORdash Par-h12 ip

Page 1: ...User Manual...

Page 2: ...urpose without written consent from Chauvet Document Printing For best results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure the p...

Page 3: ...p 8 AC Power 8 AC Plug 8 Power Linking 8 DMX Linking 9 DMX Personalities 9 Master Slave Connectivity 9 Mounting 10 Orientation 10 Rigging 10 Procedure 10 4 Operation 11 Control Panel Operation 11 Cont...

Page 4: ...NTS COLORdash Par H12 IP User Manual Rev 1 TOC 2 of 2 Fixture Hours Software Version 18 Factory Reset 18 5 Technical Information 19 Product Maintenance 19 6 Technical Specifications 20 7 Returns 21 8...

Page 5: ...H12 IP Seetronic Powerkon IP65 power cord Gel Frame Warranty Card Quick Reference Guide Convention Meaning 1 512 A range of values 50 60 A set of values of which only one can be chosen SET A button o...

Page 6: ...cm from adjacent surfaces Make sure there are no flammable materials close to the product when operating When hanging this product always secure to a fastening device using a safety cable Power and Wi...

Page 7: ...RGBAWP dimmer strobe 13 channel RGBWAP dimmer strobe color macro white balance auto speed dimmer speed Rugged RGBWA UV LED wash for events where indoor outdoor flexibility is needed At home in any we...

Page 8: ...Page 6 of 22 INTRODUCTION COLORdash Par H12 IP User Manual Rev 1 Product Overview Control Panel DMX In Out Adjustment Knob Power In Power Out Safety Loop 13 mm Mounting Point Double Bracketed Yoke...

Page 9: ...Page 7 of 22 COLORdash Par H12 IP User Manual Rev 1 INTRODUCTION Product Dimensions 12 87 in 327 mm 7 68 in 195 mm 12 05 in 306 mm 9 41 in 239 mm 6 97 in 177 mm...

Page 10: ...plug Power Linking The product supports power linking You can power link up to 26 products at 120 V up to 46 at 208 V or up to 50 at 230 V This product comes with a power input cord Power linking cab...

Page 11: ...r H12 IP the master to control one or more COLORdash Par H12 IP products the slaves without a DMX controller One COLORdash Par H12 IP becomes the master when running an auto or custom program or by be...

Page 12: ...cable Mount the product securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss use a mounting clamp of appropriate weight capacity When power linking...

Page 13: ...another programming level you will see that first option or you will see the selected value Press MENU repeatedly to exit to the previous main level Control Panel Lock This setting enables you to act...

Page 14: ...olor R Red G Green B Blue A Amber W White P Ultraviolet UV RG Red Green RB Red Blue RA Red Amber RW Red White RP Red UV GB Green Blue GA Green Amber GW Green White GP Green UV BA Blue Amber BW Blue Wh...

Page 15: ...WP Red Green Blue Amber White UV Color Temperature Warm White 1 Preset white color temperatures Warm White 2 Warm White 3 Neutral White 1 Neutral White 2 Neutral White 3 Daylight 1 Daylight 2 Daylight...

Page 16: ...or each DMX mode is as follows LED Frequency 600Hz Selects the PWM output frequency 1200Hz 2000Hz 4000Hz 6000Hz 25kHz Back Light On Display backlight always on 10S Turns off display backlight after 10...

Page 17: ...R 100 G 0 B 100 0 R 100 G 0 100 B 0 100 R 100 0 G 100 0 B 100 RGB 100 White 1 White 2 White 3 White 4 White 5 White 6 White 7 White 8 White 9 White 10 White 11 10 Color Temperature 000 005 006 025 02...

Page 18: ...Go to the Master Slave Mode main level 2 Select Master 3 Select an auto program as explained in Auto Programs or a static mix of colors Channel Function Value Percent Setting 1 Dimmer 000 255 0 100 2...

Page 19: ...other colors Color Temperature The color temperature mode allows for permanent white color temperature presets without a DMX controller 1 Go to the Static main level 2 Select Color Temperature 3 Selec...

Page 20: ...ght main level 2 Select On remains on 10S 10 seconds 20S 20 seconds or 30S seconds Fixture Hours Software Version This option displays the total number of hours the product has run the UID Universal I...

Page 21: ...eased mechanical wear To clean the product 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collecte...

Page 22: ...A 0 505 A Power linking current products 13 6 A 14 products 13 6 A 26 products Power I O U S Canada Worldwide Power input connector Seetronic Powerkon IP65 Seetronic Powerkon IP65 Power output connec...

Page 23: ...n RMA number Chauvet will refuse any product returned without an RMA number Once you have the RMA number provide the following information on a piece of paper and place it inside the box Your name You...

Page 24: ...60 Website Toll Free 800 762 1084 www chauvetlighting com EUROPE General Information Technical Support Address Stokstraat 18 Email eutech chauvetlighting eu 9770 Kruishoutem Website Belgium www chauve...

Reviews: