1. Before You Begin 

6/21/2013 12:33 PM  

Safety Instructions 

 

 

 

 

 

 

 

 

Please keep this User Manual for future consultation. If you sell the unit to another 

user, be sure that they also receive this instruction booklet. 

 

Always make sure that you are connecting to the proper voltage, and that the line 

voltage you are connecting to is not higher than that stated on the decal or rear panel 

of the fixture. 

 

This product is intended for indoor use only! To prevent risk of fire or shock, do not 

expose fixture to rain or moisture. 

 

Make sure there are no flammable materials close to the unit while operating. 

 

The unit must be installed in a location with adequate ventilation, at least 20 in (50 cm) 

from adjacent surfaces. Be sure that no ventilation slots are blocked. 

 

Always disconnect from power source before servicing or replacing fuse and be sure to 

replace with same fuse source. 

 

Secure fixture to fastening device using a safety chain. 

 

Maximum ambient temperature (Ta) is 104° F (40° C). Do not operate fixture at 

temperatures higher than this.  

 

In the event of a serious operating problem, stop using the unit immediately. Never try 

to repair the unit by yourself. Repairs carried out by unskilled people can lead to 

damage or malfunction. Please contact the nearest authorized technical assistance 

center. 

 

Never connect the device to a dimmer pack. 

 

Make sure the power cord is never crimped or damaged. 

 

Never disconnect the power cord by pulling or tugging on the cord. 

 

Never carry the fixture directly from the cord. Always use the hanging/mounting 

bracket. 

 

Avoid direct eye exposure to the light source while it is on.  

  

 

Please read these instructions carefully. It includes important information 

about the installation, usage and maintenance of this product. 
 

Summary of Contents for Comet LED

Page 1: ...User Manual ...

Page 2: ...evision 2 by AL Release Date 11 11 2010 TABLE OF CONTENTS 1 BEFORE YOU BEGIN 3 WHAT IS INCLUDED 3 UNPACKING INSTRUCTIONS 3 MANUAL CONVENTIONS 3 ICONS 3 SAFETY INSTRUCTIONS 4 2 INTRODUCTION 5 PRODUCT OVERVIEW 5 3 SETUP 6 AC POWER 6 Power Linking 6 MOUNTING 7 Orientation 7 Rigging 7 4 OPERATING INSTRUCTIONS 8 STANDALONE 8 Sound Active 8 5 APPENDIX 9 GENERAL TROUBLESHOOTING 9 GENERAL MAINTENANCE 9 RE...

Page 3: ...gular text CONVENTION MEANING 10 A DIP switch to be configured Menu A key to be pressed on the fixture s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings A sequence of menu options to be followed ON A value to be entered or selected Icons This man...

Page 4: ...ect from power source before servicing or replacing fuse and be sure to replace with same fuse source Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by u...

Page 5: ...2 Introduction 5 6 21 2013 12 33 PM 2 INTRODUCTION Product Overview Back Panel Voltage Selection Switch 115 230 VAC Power Out Microphone Microphone Sensitivity Adjustment Knob Power In Fuseholder ...

Page 6: ...he fixture to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used only as a 0 to 100 switch Always connect the fixture to a circuit with a suitable electrical ground Power Linking This fixture contains power linking via the Edison outlet located in front of the power input cable Please see the diagram below for further explanation The maximum quantity of C...

Page 7: ... is 13 mm in size When rigging consider routine maintenance and control panel access Please see the following notes on installation If the power link out is intended to be used with multiple fixture take into account the length of each power cable and mount the fixtures close enough to one another to accommodate for this When aiming the fixtures you may use the bracket adjustment knob Loosen the k...

Page 8: ...ions 8 6 21 2013 12 33 PM 4 OPERATING INSTRUCTIONS Standalone Sound Active This fixture has a preprogrammed sound triggered chase Adjust the microphone sensitivity from the control panel No additional settings are required ...

Page 9: ... Gently polish optical surfaces until they are free of haze and lint Always dry the parts carefully after cleaning them Never spin a fan using compressed air Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandize Authorization Number RMA Products returned without the RMA will be ...

Page 10: ...hite Rating 1 W 330 mA 50 000 hrs PHOTO OPTIC Coverage angle 90 INDOOR OUTDOOR Rating For indoor use only THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION Comet LED COMETLED WARRANTY INFORMATION Warranty 1 year limited warranty CONTACT US WORLD WIDE General Information CHAUVET 5200 NW 108 th Ave Sunrise FL 33351 voice 954 577 4455 fax 954 929 5560 toll free 800 762 1084 Technica...

Reviews: