background image

Replacing Fuses

I

f  one of the channels does not function at all when connected to the main power supply, then it is highly likely that the

fuse has blown.

Disconnect from main power supply before attempting to replace either lamps or fuse.

In order to replace the fuse, disconnect from the main power supply first, and then unscrew the fuseholder cover to
reveal the fuse. The unit is clearly marked indicating the correct fuse rating. It is most important that replacement fuses
are of the correct rating. Failure to use the correct fuse could damage the unit beyond economic repair.

The fuse should simply be placed inside the holder and the screw cap replaced, when this is done connect to the main
power supply to check. If the unit is still not working then please contact your dealer or 
CHAUVET for servicing.

Maintenance & Servicing

Work on internal parts should be carried out by a qualified technician. Removal of covers other than the front to replace
lamp or effect dish, or the fuseholder is considered a breach of warranty and will not be covered under any such 
agreement unless authorized first by the company.

Specifications:

Input Power:

110V, 60Hz

Maximum Load:
Total:

20 Amps

Per Channel:

7 Amps

Fuse:

7 Amps, 125V