background image

 

 

 

 

 

 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

 

 

LASER LIGHT 

AVOID DIRECT EYE EXPOSURE 

CLASS 3R LASER PRODUCT 

CLASSIFIED PER EN/IEC 60825-1:2007 

Complies with FDA performance standards 

for laser products except for deviations 

pursuant to Laser Notice No. 50, dated  

June 24, 2007. 

Summary of Contents for eclipse

Page 1: ...AVOID DIRECT EYE EXPOSURE CLASS 3R LASER PRODUCT CLASSIFIED PER EN IEC 60825 1 2007 Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No 50 dated June 24 2007 ...

Page 2: ...E 11 4 OPERATING INSTRUCTIONS 12 GENERAL TROUBLESHOOTING 13 RETURNS PROCEDURE 13 CONTACT INFORMATION 13 TECHNICAL SPECIFICATIONS 14 Contact Information World Headquarters United Kingdom Ireland CHAUVET CHAUVET Europe Ltd General Information Address 5200 NW 108th Avenue Sunrise FL 33351 Voice 954 929 1115 Fax 954 929 5560 Toll free 800 762 1084 Technical Support Voice 954 929 1115 Press 4 Fax 954 7...

Page 3: ...dise Manual Conventions CHAUVET manuals use the following conventions to differentiate certain types of information from the regular text Convention MEANING Menu A key to be pressed on the product s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the operating mode current status MENU Settings...

Page 4: ... the nearest authorized technical assistance center Never connect this product to a dimmer pack Make sure the power cord is not crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Never carry a product from the power cord or any moving part Always use the hanging mounting bracket or the handles Always avoid direct eye exposure to the light source when this product ...

Page 5: ...people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do not operate the laser without first reading and understanding all safety and technical data in this manual Always set up and install all laser effects so that all laser light is at least 3 meters 9 8 feet above the floor on which people can stand See Proper Usage section later in this manual Af...

Page 6: ...Eclipse User Manual 6 8 18 2011 Laser Safety Label Reproduction LASER HAZARD WARNING LABEL LASER APERTURE LABEL EXPLANATORY MANUFACTURER S ID CERTIFICATION LABEL NON INTERLOCKED HOUSING LABEL ...

Page 7: ...Data Laser Classification Class 3R Green Laser Medium DPSS Nd YVO4 532nm Red Laser Medium LD GaAlAs 650nm typical Beam Diameter 5mm at aperture Pulse Data All pulses 4Hz 0 25sec Divergence each beam 2 mrad Divergence total light 160 degrees Laser Power of Each Beam from Aperture 5mW As measured under IEC measurement conditions for classification Laser Compliance Statement This laser product compli...

Page 8: ...Eclipse User Manual 8 8 18 2011 2 INTRODUCTION Product Overview Bracket adjustment knob 1 of 2 LED output Laser Aperture ...

Page 9: ...Eclipse User Manual 9 8 18 2011 Product Dimensions ...

Page 10: ... dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Mounting Orientation This product may be mounted in any safe position provided there is adequate room for ventilation Rigging It is important never to obstruct the fan or vents pathway Mount the product using a suitable C or O type clamp Adjust the angle of the product by loosening both knobs and tilting th...

Page 11: ...ing hardware from your lighting vendor International laser safety regulations require that laser products must be operated in the fashion illustrated below with a minimum of 3 meters 9 8 ft of vertical separation between the floor and the lowest laser light vertically Additionally 3 meters of horizontal separation is required between laser light and audience or other public spaces CAUTION USE OF C...

Page 12: ...een strobe knob Turn clockwise to increase the strobe speed of the green laser from slow to full on LED rotation button Push in rotate counterclockwise Push out rotate clockwise LED rotation speed knob Turn clockwise to increase the rotation speed of the deep blue LED effect from static to full speed LED brightness knob Turn clockwise to increase the intensity of the deep blue LED effect from off ...

Page 13: ...the product Be prepared to provide the model number serial number and a brief description of the cause for the return Be sure to properly pack product any shipping damage resulting from inadequate packaging is the customer s responsibility CHAUVET reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method ...

Page 14: ... 0 2 A max 120 V Inrush Current 0 1 A 120 V Power Consumption 18 W 0 1 A max 230 V Inrush Current 0 2 A 230 V Power Output 50 units max 120 V 90 units 230V LIGHT SOURCE LED 5W 1 000 mA 1 deep blue 450 nm 50 000 hrs LASER Green diode 532 nm 30 mW Red diode 650 nm 80 mW Laser Type DPSS Cooling Fan Cooled RANGE Coverage Angle 120 THERMAL Maximum ambient temperature 104 F 40 C ORDERING INFORMATION Ecl...