background image

 

 

 

 

Appendix 

ILS-606 & ILS-625 User Manual 

19 

 

2005-03-09/22:45 

General Troubleshooting 

Applies to 

Symptom 

Solution(s) 

Lights 

Foggers 

& Snow 

Controllers 

Dimmers

& Chaser 

Auto shut off 

Check fan thermal switch reset 

 

 

 

 

Beam is very dim or not 
bright 

Clean optical system or replace lamp 
Check 220/110v switch for proper setting 

 

 

 

 

Breaker/Fuse keeps 
blowing 

Check total load placed on device 

 

 

 

 

Chase is too slow 

Check users manual for speed adjustment 

 

 

 

 

Device has no power 

Check for power on Mains. 
Check device

s fuse. (internal and/or external)

 

 

 

 

 

Fixture is not responding  Check DMX Dip switch settings for correct addressing 

Check DMX cables 
Check polarity switch settings  

 

 

 

 

Fixture is on but there is 
no movement to the 
audio 

Make sure you have the correct audio mode on the control 
switches. If audio provided via 

¼

 jack, make sure a live audio 

signal exists 
Adjust sound sensitivity knob 

 

 

 

 

Lamps cuts off 
sporadically  

Possible bad lamp or fixture is overheating. 
Lamp may be at end of its life. 

 

 

 

 

Light will not come on 
after power failure 

Some discharge lamps require a cooling off period before the 
electronics in the fixture can kick start it again, wait 5 to 10 
minutes before powering up 

 

 

 

 

Loss of signal 

Use only DMX cables 
Install terminator 
Note: Keep DMX cables separated from power cables or black 
lights. 

 

 

 

 

Motor movements are 
jerky or jumpy 

Possible bad motor driver or sensors 
Check  polarity switch on controller 

 

 

 

 

Moves slow 

Check 220/110v switch for proper setting 

 

 

 

 

No flash 

Re-install bulb, may have shifted in shipping 

 

 

 

 

No light output 

Check slip ring & brushes for contact  
Install bulb 
Call service technician 

 

 

 

 

Relay will not work 

Check reset switch 
Check cable connections 

 

 

 

 

Remote does not work 

Make sure connector is firmly connected to device 

 

 

 

 

Stand alone mode 

All CHAUVET lighting fixtures featuring stand-alone functions 
do not require additional settings, simply power the fixture and 
it will automatically enter into this mode 

 

 

 

 

Unit wobbles when 
rotating 

Check for damages possibly incurred during shipping 

 

 

 

 

Summary of Contents for ILS-606DBR

Page 1: ... 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 03 09 22 45 ILS 606DBR ILS 606DSR ILS 625DCR USER MANUAL This manual includes instructions and overview on the following 3 CHAUVET products ILS 606DBR ILS 606DSR and ILS 625DCR ...

Page 2: ... 9 Setting the starting address 10 Master Slave settings SLNd SL 1 SL 2 10 Setting the alternate slave mode SL 2 10 User Configurations CLNd IPan ItLt Irot 606DBR IdIN 11 Color Mode CLNd 11 Pan Invert IPan tilt Invert ItLt Irot 11 Segment Display Configurations Led IdSP 11 Turning the Display off Led 11 Display Inverse IdSP 11 Fixture Test and Service Functions FAdJ teSt FhrS rSet 12 Focus Adjustm...

Page 3: ... circuits with a suitable Earth Ground Safety Instructions Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is ...

Page 4: ...06DSR Tilt 2 Gobos 3 Shutter 3 Color 4 Gobos 4 Gobo Rotation 5 Color 5 Dimmer 6 Gobo Rotation 7 Dimmer What is ILS ILS stands for Integrated Lighting System CHAUVET fixtures with the ILS logo are equipped with an advanced independent show technology that enables synchronization across all intelligent lighting fixtures within the group Gobos colors and chases are among the various features that syn...

Page 5: ...s in the Master operating mode Slave On Unit is in the Slave operating mode Sound Flashing Sound Active mode is on SEGMENT BUTTONS I O PANEL OVERVIEW BUTTONS I O PANEL MENU Toggles programming functions DMX Out In DMX 512 connectors DOWN Steps backward through menu functions MIC Built in microphone UP Steps forward through menu functions Sensitivity POT Sets audio sensitivity ENTER Confirms select...

Page 6: ...lean the glass envelope of the bulb with an alcohol wipe or equivalent 6 Holding the lamp socket plate insert the tip of the lamp into the fixture with extreme care Navigate the lamp all the way until it reaches the reflector and the lamp base plate touches the bottom plate of the fixture 7 Align the screw holes and fasten the thumbscrews back onto the lamp socket plate 8 If you are replacing the ...

Page 7: ...th knobs and tilting the fixture After finding the desired position retighten both knobs When selecting installation location take into consideration lamp replacement access and routine maintenance Safety cables should always be used Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Lamp Alignment LAMP ALIGNMENT HOW ...

Page 8: ...mmer Inverse OPERATING INSTRUCTIONS Menu Navigation To select any of the pre set functions press the MENU button until the desired function is shown on the display Select the function by pressing the ENTER button and the display will blink Use the DOWN and UP button to change the settings Once the required setting has been selected press the ENTER button to activate it If you don not press the ENT...

Page 9: ...ber is pre fixed by the letters ILS Master Slave operation does not require any menu or setting selections Simply connect each fixture in a daisy like fashion using qualified 3 pin DMX cables as described below The first unit in the chain will operate in a Stand Alone mode and all units following will synchronize to the first unit 1 Connect the male 3 pin connector side of the DMX cable to the out...

Page 10: ...elect DMX addressing Once selected the display will read either a 1 or any other number that may have previously been set You must make a selection within 6 seconds 3 Press the UP and DOWN buttons to increase or decrease values until the desired value is achieved 4 Press the ENTER button to activate selection Master Slave settings SLNd SL 1 SL 2 By linking the units under a master slave control mo...

Page 11: ...of the rest You can apply a pan and tilt Invert by following these instructions 1 Tap the MENU button until the display reads IPan or ItLt 2 Press the ENTER button to select this function The selection is confirmed when the display begins to blink You must make a selection within 8 seconds 3 Press the UP and DOWN buttons to toggle between the I for inverse and no for none 4 Press the ENTER button ...

Page 12: ... including gobo and color effects 1 Tap the MENU button until the display reads teSt 2 Press ENTER and the fixture will immediately begin to play back a test sequence Observe tentatively for any abnormalities 3 Press the MENU button to leave this mode FIXTURE RESET RSET This function will re initialize the fixture by returning all motors to its startup positions or otherwise known as home position...

Page 13: ...c strobe 2 sync strobe 3 two light strobe LED blinks normal Sound Fixture 606DBR 606DSR X Y moving patterns 12 patterns user selectable Fixture 625DCR Chase Pattern selection 6 patterns LED on Slow Sound Fixture All Color Gobo selection Hold for gobo change tap for color change BLACKOUT LED blinks fast Position Fixture 606DBR 606DSR X Y moving position dimmer setting Fixture 625DCR Dimmer setting ...

Page 14: ...f one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 whil...

Page 15: ...w Fast gobo scroll 5 normal 000 012 013 025 026 038 039 051 052 063 064 076 077 089 090 102 103 115 116 127 128 255 CS 000 007 008 015 016 022 023 030 031 037 038 045 046 052 053 060 061 067 068 075 076 082 083 090 091 097 098 105 106 112 113 120 121 127 128 255 Color normal Open white Green Magenta Light Blue Yellow Orange Blue UV Purple Light Green Pink Slow Fast color scroll CS color split mode...

Page 16: ...255 CS 000 007 008 015 016 022 023 030 031 037 038 045 046 052 053 060 061 067 068 075 076 082 083 090 091 097 098 105 106 112 113 120 121 127 128 255 Color normal Open white Green Magenta Light Blue Yellow Orange Blue UV Purple Light Green Pink Slow Fast color scroll CS color split mode Open white Green Green Magenta Magenta Magenta Light Blue Light Blue Light Blue Yellow Yellow Yellow Orange Ora...

Page 17: ... 625 User Manual 17 2005 03 09 22 45 Gobos 606DBR 606DSR Open Dots Tunnel Broken Glass Swirl Cylinder Frost Breakup Triangle 4 Dots 625 DCR Open Dots Tunnel Broken Glass Frost Cylinder Frost Breakup 3200 K 6600 K ...

Page 18: ... the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid ...

Page 19: ...Possible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Motor movem...

Page 20: ...OTO OPTIC Beam Angle 14 Pan ILS 606 180 Tilt ILS 606 70 THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 10A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Protocols DMX 512 USITT DMX Channels 606xxx 7 DMX Channels 625DCR 5 ORDERING INFORMATION Trackscan 250DBR ILS B...

Reviews: