ILS-606 & ILS-625 User Manual
8
2005-03-09/22:45
MENU
Addr
DMX-512 Address Setting
SLNd
bLNd
CLNd
IPan
ItLt (606DSR)
or
Irot (606DBR)
LEd
IdSP
FAdJ
Focus adjust
test
Self test
FhrS
Fixture hours
rSeT
Reset
1 ~ 512
SL I
Slave mode
“
Normal
”
SL 2
Slave mode
“
2 Light Show
”
Y bo
Blackout mode
“
Yes to Blackout
”
N bo
Blackout mode
“
No to blackout
”
No
Normal Color
SC
Split Color
No
Pan Normal
I
Pan Inverse
No
606DSR
–
Tilt Inverse
606DBR
–
Barrel Rotation Inverse
I
606DSR - Tilt Normal
606DBR - Barrel Rotation Normal
OFF
Display Off
ON
Display On
IdSP
Display Inverse
dSPI
Display Normal
Figure 3 - Display Panel Diagram
IdIN
No
Dimmer Normal
I
Dimmer Inverse
O
PERATING
I
NSTRUCTIONS
Menu Navigation
To select any of the pre-set functions, press the MENU button until the desired function is shown on the
display. Select the function by pressing the ENTER button and the display will blink. Use the DOWN and
UP button to change the settings. Once the required setting has been selected, press the ENTER button to
activate it. If you don not press the ENTER button, it will automatically return to the main functions without
any change after idling 8 seconds. To go back to the functions without any change press the MENU
button. The main functions are shown below:
Upon powering up the unit, you will notice that it will display a fixture ID. In addition, the fixtures electronics
will load up its programming and home (adjust) its motors to a starting position. The sequence of events