background image

 

Intimidator

 2.0 HTI User Manual

 

2006-07-14/15:32

 

Optional Controller 

Daisy Chain 

Connection 

O

PERATING 

I

NSTRUCTIONS

 

Operating Modes 

 

 

A stand-alone mode will listen to sound and run through its diverse range of built in programs.  

 

Master/Slave mode will allow the command of up to as many units you want in a synchronized light show to the 
sound. 

 

DMX control mode will provide the greatest flexibility and creativity. Each fixture trait can be controlled individually 
using any universal DMX-512 controller.  

Stand Alone 

The Stand Alone mode is activated automatically when the fixture is absent of DMX signal or a 

controller is not connected. The fixture will run through its built in programs as it listens to the sound. 

Master/Slave 

The Master/Slave mode will allow you to link up to as many units you want in a daisy chain fashion. In 

this mode, the first unit in the daisy chain will automatically command all other units following. 

Connecting this fixture for (Master/Slave) operation does not require any menu or setting selections. 

Simply connect each unit in a daisy like fashion using qualified 3 pin DMX cables as described below.  

M AST E R / S L AV E   S ET T I N G S 

1) 

Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector 
of the first fixture.  

2) 

Connect the end of the cable coming from the first fixture which will have a (female) 3 pin 
connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, 
proceed to connect from the output as stated above to the input of the following fixture and so on 
as illustrated below.  

Note!  

For additional information on linking fixtures read under section 

DMX Primer

 

DMX Mode 

Operating in a DMX Control mode environment gives the user the greatest flexibility when it comes to 

customizing or creating a show.  In this mode you will be able to control each individual trait of the 

fixture independently.  

S ET T I N G   T H E  ST AR T I N G   AD D R E SS 

This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start 

address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data 

on the channel indicated by the start address. For example, a fixture that occupies or uses 6 channels 

of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 

102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap and notate 

the start address selected for future reference.  

Summary of Contents for Intimidator 2.0 HTI

Page 1: ...Chauvet 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2006 07 14 15 32 Intimidator 2 0 HTI USER MANUAL Intimidator 2 0 HTI ...

Page 2: ...ETUP 6 LAMP 6 Lamp installation 6 POWER 6 MOUNTING 8 Orientation 8 Rigging 8 MANUAL FOCUSING 8 FUSE REPLACEMENT 8 OPERATING INSTRUCTIONS 9 OPERATING MODES 9 Stand Alone 9 Master Slave 9 Master Slave settings 9 DMX Mode 9 Setting the starting address 9 CA 9 EASY CONTROLLER OPTIONAL 11 APPENDIX 12 DMX PRIMER 12 Fixture Linking 12 DMX CHANNEL VALUES 13 MAINTENANCE 14 RETURNS PROCEDURE 14 CLAIMS 14 GE...

Page 3: ... this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not e...

Page 4: ...in 5 sec Tilt 90 in 3 sec Features Built in beat activated and automatic programs stand alone Double bracket yoke doubles as floor stand Bulb saver cuts off after 10 seconds Surface coated mirror for optimum luminosity Automatically enters stand alone when no DMX signal is present Linkable via Master Slave Micro stepping motors Thermal switch Fan cooled Options Wired remote controllers CA 9 Easy C...

Page 5: ...timidator 2 0 HTI Mirror Scanner Hanging Yoke double bracketed for floor positioning Double bracketed yoke used for floor positions Lamp access cover Power Fuse compartment Microphone Sound Sensitivity Knob Voltage Switch Remote Controller Input DMX connectors Dipswitches ...

Page 6: ...rt the lamp squarely until the retaining clips on the lamp socket secure the lamp tightly 4 Clean the glass envelope of the bulb with an alcohol wipe or equivalent 5 Holding the lamp socket plate insert the tip of the lamp into the fixture with extreme care Navigate the lamp all the way until it reaches the reflector and the lamp base plate touches the bottom plate of the fixture 6 Align the screw...

Page 7: ...t up or down within the reflector 4 As you move in and out of optimum lamp focus you will see the hot spot either gets wider or narrower The goal is to either totally diminish the hot spot by having it widen and spread across the entire spot or moving the hot spot so that it covers as much of the beam spot area as possible Power Your product is equipped with switch selectable AC power setting Warn...

Page 8: ...nce o Safety cables should always be used o Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Manual Focusing To adjust the focus please follow the instructions below 1 If operating in stand alone mode turn the music down so that the unit temporarily stops any activity 2 In DMX control mode create a static scene with...

Page 9: ...elow MASTER SLAVE SETTINGS 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector Then proceed to connect from the output as stated above to the input of the ...

Page 10: ...provide the start address Determining which switches to toggle ON given a specific start address can be accomplished in the following manner By subtracting the largest switch value possible from the selected start address which does not cause a negative number EXAMPLE STARTING ADDRESS Address 10 Pin 4 8 Pin 2 2 Total 10 Address 24 Pin 5 16 Pin 4 8 Total 24 Resolving address using simple math Addre...

Page 11: ...utton Tap the Function button to step through the 11 colors then once more to step to the next gobo BLACKOUT LED OFF Fast Mode The unit s movement Pan Tilt and Gobo Color is sound activated Press and hold the Function button to achieve the following results a Strobe in different colors and gobos b Synchronous strobe in white c Two light strobe in white color CA 9 Easy Controller Optional ...

Page 12: ... of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors The shield connection is pin 1 wh...

Page 13: ...31 032 039 040 047 048 055 056 063 064 071 072 079 080 087 088 095 096 103 104 111 112 119 120 127 128 255 Gobo Blackout Open Gobo 1 Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Gobo 9 Gobo 10 Gobo 11 Gobo 12 Gobo 13 Gobo 14 Gobo Spin Slow Fast 3 000 010 011 012 022 023 033 034 044 045 055 065 066 076 077 087 088 098 099 109 110 120 121 127 128 255 Color Open White Red Dark Blue Yellow Green P...

Page 14: ...ends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent p...

Page 15: ...y Possible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights Motor mov...

Page 16: ...eak 168W 120V inrush 360W 120V European version 230V 240V 50 Hz LAMP HTI150 150W 6500 K 750hrs PHOTOMETRICS Illuminance 1 800fc or 19 368lux 1 meter Beam Angle 12 THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 6 3A Fast Blow CONTROL PROGRAMMING Data input locking 3 pin XLR male socket Data output locking 3 pin XLR female socket Data pin configuration pin 1 shield pin 2 pin 3 Pro...

Reviews: