Intimidator Spot Duo 155 QRG
EN
4
Fuse
Replacement
1.
Disconnect the product from power.
2.
Wedge the tip of a flat-head screwdriver, loosen the fuse holder and pull
straight out.
3.
Remove the blown fuse from the safety cap and replace with a fuse of the
exact same type and rating.
4.
Re-insert the fuse holder.
5.
Reconnect the product to power.
Mounting
Before mounting this product, read the
Safety Notes
.
Mounting
Diagram
When using only one mounting clamp with this fixture, you must use a
clamp with a captive bolt to prevent accidental loosening.
Control Panel
Description
Button
Function
<MENU>
Exits from the current menu or function
<UP>
Navigates upwards through the menu list and increases the
numeric value when in a function
<DOWN>
Navigates downwards through the menu list and decreases
the numeric value when in a function
<ENTER>
Enables the currently displayed menu or sets the currently
selected value into the selected function
Tripod Insertion
Hanging Bracket
Rubber Feet
Mounting Clamp
Safety Cable