background image

Safety Instructions 

 

Please read these instructions carefully, which includes important 
information about the installation, usage and maintenance of this 
product. 

 

 

 

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that 
they also receive this instruction booklet. 

 

Always make sure that you are connecting to the proper voltage, and that the line voltage you are 
connecting to is not higher than that stated on the decal or rear panel of the fixture. 

 

This product is intended for indoor use only! 

 

To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no 
flammable materials close to the unit while operating. 

 

The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent 
surfaces. Be sure that no ventilation slots are blocked. 

 

Always disconnect from power source before servicing or replacing fuse and be sure to replace with 
same fuse size and type. 

 

Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use 
its carrying handles. 

 

Maximum ambient temperature (Ta) is 104°F (40°C). Do not operate fixture at temperatures higher 
than this.  

 

In the event of a serious operating problem, stop using the unit immediately. Never try to repair the 
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please 
contact the nearest authorized technical assistance center. Always use the same type spare parts. 

 

Don’t connect the device to a dimmer pack. 

 

Make sure the power cord is never crimped or damaged. 

 

Never disconnect the power cord by pulling or tugging on the cord. 

 

Avoid direct eye exposure to the light source while it is on.  

 

Do not daisy chain power to more than 8 units.  

 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or 
attempt any repairs yourself. In the unlikely event your unit may require service, 
please contact CHAUVET at: 954-929-1115. 

 

 
 
 
 

LEDSplash 2 User Manual 

2008-01-22/09:14

 

Summary of Contents for LEDsplash 2

Page 1: ...Activated DMX512 Master Slave Autoswitching Transformer Replaceable Fuse User Serviceable Duty Cycle LEDsplash 2 USER MANUAL Chauvet 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 F...

Page 2: ...n Conversion Chart 8 SETTING UP A DMX SERIAL DATA LINK 8 MASTER SLAVE FIXTURE LINKING 9 MOUNTING 9 Orientation 9 Rigging 9 4 OPERATING INSTRUCTIONS 10 OPERATION 10 Stand Alone Mode Sound Active Auto M...

Page 3: ...ching power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range...

Page 4: ...acing fuse and be sure to replace with same fuse size and type Secure fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its carrying handles Maximum ambie...

Page 5: ...e LED Techno Strobe RGB LEDsplash 200B and LEDsplash 2 in stand alone DMX Channel Summary 1 2 3 4 5 6 RGB 000 029 Red 000 255 Green 000 255 Blue 000 255 Pulse 030 119 Slow Fast No Function Strobe 000...

Page 6: ...acket Sound Sensitivity Knob Music Auto Switch Microphone Dipswitches Power Connector and Fuse Holder DMX Output Connector Power Output max 8 units LEDsplash 2 only DMX Input Connector LEDSplash 2 Use...

Page 7: ...y isolated splitter may result in deterioration of the digital DMX signal Maximum recommended serial data link distance 500 meters 1640 ft Maximum recommended number of fixtures on a serial data link...

Page 8: ...pin adapter CHAUVET Model No DMX5M or DMX5F The chart below details a proper cable conversion 3 PIN TO 5 PIN CONVERSION CHART Conductor 3 Pin Female output 5 Pin Male Input Ground Shield Pin 1 Pin 1...

Page 9: ...slave setting Please consult the Operating Instructions section in this manual for complete instructions for this type of setup and configuration Mounting ORIENTATION This fixture may be mounted in an...

Page 10: ...he Master Slave mode will allow you to link up to as many units you want in a daisy chain fashion In this mode the first unit in the daisy chain will automatically command all other units following 1...

Page 11: ...de allows the unit to be controlled by any universal DMX controller If you are unfamiliar with DMX please read the DMX Primer on page 15 1 A working DMX 512 signal source plugged into the LEDsplash 2...

Page 12: ...016 Red 017 056 Red Full Green 0 100 057 094 Green Full Red 100 0 095 096 Green 097 136 Green Full Blue 0 100 137 174 Blue Full Green 100 0 175 176 Blue 177 216 Blue Full Red 0 100 Color Macro Ch 1 12...

Page 13: ...its life 9 Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before poweri...

Page 14: ...fixtures whose starting address is set incorrectly You can however control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement...

Page 15: ...y 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clear...

Page 16: ...ing Inrush Power 1 4A Power Factor 0 63 LIGHT SOURCE LED 24 8 red 8 green 8 blue 50 000hrs PHOTO OPTIC Beam Angle 11 8 Field Angle 22 Illuminance at 1m 5 627 lux THERMAL Maximum ambient temperature 10...