COLORado ™Panel Service Maintenance Guide
Symptom(s) Possible
Solution(s)
1 or more LED’s are not
illuminating
Clean the fixture regularly to avoid any such failure. This fixture is convection
cooled, which means that if the surface is kept clean and free of debris, then
proper cooling will be allowed to occur
An LED may have failed, resulting in an open circuit. In this event, all of the
red, green, or blue in a single module will no longer illuminate. This does not
mean that all of the LEDs have failed, but the circuit is wired in series.
An LED may have failed, resulting in a short circuit. In this event, only the
single LED which has failed will no longer function. This does not mean that all
of the LEDs have failed, but the circuit is wired in series.
-Note: In the event of LED failure, a replacement LED PCB assembly may be
purchased directly from Chauvet Part#: P222-CPNLLED
1 or more LED’s are producing
very low output
Check that the lens assembly is installed properly. If the lens assembly is not
aligned properly over the LEDs, then they will not project fully
-See section on Lens Assembly Installation
-Note: In the event of LED failure, a replacement LED PCB assembly may be
purchased directly from Chauvet Part#: P222-CPNLLED
Breaker/Fuse keeps blowing
Check total load placed on the electrical circuit
Check for a short in the electrical wiring: internal and/or external
Device has no power
Check device’s fuse (internal)
Check for power on Mains
Check cable connections The COLORado™Panel IP-66 cables must be firmly
connected and locked in place for operation
-Note: In the event of autoswitching transformer failure, the unit can be sent in
for repair; however, a replacement part can be ordered directly from Chauvet
Part#: P140-CPELTR
Fixture is not responding to DMX
Check Control Panel settings for correct addressing
Check DMX cables
Check polarity switch settings on the controller
Check cable connections
Call service technician
-Note: In the event of Master PCB failure, a replacement PCB can be ordered
directly from Chauvet Part#: P170-CPDSPL
Loss of signal
Use only DMX cables
Install
terminator
Note: Keep DMX cables separated from power cables or black lights
COLOR-CON Controller does
not function, or does not function
properly
Make sure connector is firmly connected to device
The COLORado™Panel fixture must be in the correct mode in order to
properly respond to the COLOR-CON controller. The correct mode is “SLAVE”
in the onboard Control Panel
Stand alone operation
This fixture has built-in, automatic programs that may be triggered from the
onboard Control Panel
Display reading:
“High ˆT”
The COLORado™Panel features a thermal protection that will be implemented
in the event of over-heating. This can occur if the fixture in not in an ideal
location for the convection cooling to be effective
If you still have a problem after trying the above solutions, please contact CHAUVET
Technical Support at the location on page 28.
COLORado™ Panel User Manual
32
4/25/2008 3:29 PM
Summary of Contents for Panel
Page 31: ...Photometrics COLORado Panel User Manual 31 4 25 2008 3 29 PM ...
Page 35: ...LED PCB P222 CPNLLED COLORado Panel User Manual 35 4 25 2008 3 29 PM ...
Page 36: ...LED Driver PCB Schematics COLORado Panel User Manual 36 4 25 2008 3 29 PM ...
Page 37: ...Display Master PCB Schematics COLORado Panel User Manual 37 4 25 2008 3 29 PM ...
Page 38: ...COLORado Panel User Manual 38 4 25 2008 3 29 PM ...