AC Power
This fixture has an auto-switching switch-mode power supply that can accommodate a wide range of
input voltages. The only thing necessary to do before powering on the unit is to make sure the line
voltage you are applying is within the range of accepted voltages. This fixture will accommodate
between 100V and 240V AC 50-60 Hz. All fixtures must be powered directly off a switched circuit and
cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer
channel is used solely for a 0% to 100% switch.
This fixture is designed for power linking from one COLORado™Panel to another COLORado™Panel
fixture. Each fixture ships with IP-66 proprietary power input cables. Each fixture ships with a power
adapter to Male Edison connector.
Warning!
All fixtures must be connected to circuits with a suitable Earth Ground.
Depending on the application, the lighting fixture may require a different connector Please refer to the
below wire color code if installing a new connector.
Wire Connection
Brown AC
Live
Blue AC
Neutral
Green/Yellow AC
Ground
Connection Pin
AC Live
1
AC Neutral
2
Ground(Earth) 3