Troubleshooting 

Symptom 

Solution(s) 

Applies to 

Lights 

 

Controllers 

 

Auto shut off 

Check fan thermal switch reset 

 

 

Beam is very dim or 
not bright 

Clean optical system or replace lamp 
Check 220/110 v switch for proper setting 

 

 

Breaker/Fuse keeps 
blowing 

Check total load placed on device 

 

 

Device has no power 

Check for power on Mains 
Check device’s fuse (internal and/or external) 

 

 

Fixture is not 
responding 

Check DMX Dip switch settings for correct addressing 
Check DMX cables 
Check polarity switch settings  

 

 

Fixture is on but 
there is no 
movement to the 
audio 

Make sure you have the correct audio mode on the 
control switches. If audio provided via ¼

 jack, make 

sure a live audio signal exists 
Adjust sound sensitivity knob 

 

 

Lamps cuts off 
sporadically  

Possible bad lamp or fixture is overheating 
Lamp may be at end of its life 

 

 

Light will not come 
on after power failure 

Some discharge lamps require a cooling off period 
before the electronics in the fixture can kick start it 
again, wait 5 to 10 minutes before powering up 

 

 

Loss of signal 

Use only DMX cables 
Install terminator 
Note: Keep DMX cables separated from power cables 
or black lights. 

 

 

Moves slow 

Check 220/110v switch for proper setting 

 

 

No flash 

Re-install bulb, may have shifted in shipping 

 

 

No laser output 

Bounce mirror motor may have shifted during shipping, 
readjust  

 

 

Standalone mode 

All Chauvet® lighting fixtures featuring standalone 
functions do not require additional settings, simply 
power the fixture on and it will automatically enter into 
this mode 

 

 

 

If you still have a problem after trying the above solutions, please contact CHAUVET® Technical Support. 

 

 

 

Summary of Contents for Scorpion Storm FXRG

Page 1: ...VOID DIRECT EYE EXPOSURE CLASS 3R LASER PRODUCT CLASSIFIED PER EN IEC 60825 1 2007 Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No 50 dated...

Page 2: ...ON 6 LASER EMISSION DATA 7 LASER COMPLIANCE STATEMENT 7 2 INTRODUCTION 8 PRODUCT OVERVIEW 8 PRODUCT DIMENSIONS 8 3 SETUP 10 AC POWER 10 FUSE REPLACEMENT 10 MOUNTING 10 Orientation 10 Rigging 10 PROPER...

Page 3: ...lated to shipping or concealed damage file a claim with CHAUVET within 7 days of receiving the merchandise Manual Conventions CHAUVET manuals use the following conventions to differentiate certain typ...

Page 4: ...ple can lead to damage or malfunction Please contact the nearest authorized technical assistance center Never connect this product to a dimmer pack or rheostat Make sure the power cord is not crimped...

Page 5: ...ich people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do not operate the laser without first reading and understanding all safety and technical data...

Page 6: ...Scorpion Storm FXRG User Manual 6 Rev 3 Laser Safety Label Reproduction LASER HAZARD WARNING LABEL LASER APERTURE LABEL EXPLANATORY MANUFACTURER S ID CERTIFICATION LABEL NON INTERLOCKED HOUSING LABEL...

Page 7: ...Data LASER CLASSIFICATION CLASS 3R Green Laser Medium DPSS Nd YVO4 532 nm Red Laser Medium LD GaAlAs 650 nm typical Beam Diameter 5mm at aperture Pulse Data All pulses 4 Hz 0 25 sec Divergence each be...

Page 8: ...Scorpion Storm FXRG User Manual 8 Rev 3 2 INTRODUCTION Product Overview Power LED Hanging bracket Bracket adjustment knob 1 of 2 Audio LED Laser Aperture...

Page 9: ...Scorpion Storm FXRG User Manual 9 Rev 3 Product Dimensions...

Page 10: ...its holder and replace with exact same type of fuse Insert the fuse holder back in its place and reconnect power Disconnect the power cord before replacing a fuse and always replace with the same typ...

Page 11: ...ropriate mounting hardware from your lighting vendor International laser safety regulations require that laser products must be operated in the fashion illustrated below with a minimum of three 3 mete...

Page 12: ...le line To comply with the EIA 485 standard no more than thirty two 32 fixtures should be connected on one data link Connecting more than thirty two 32 fixtures on one serial data link without the use...

Page 13: ...thout changing the value press MENU Menu Functions MAIN FUNCTION SELECTION DESCRIPTION VALUES DMX mode 001 001 506 DMX starting address assignment Standalone modes AFr Automatic fast red ASr Automatic...

Page 14: ...robing Red Green strobing Red green alternate strobing 3 000 004 005 254 255 255 Strobe No function Strobe slow fast Strobe to sound 4 000 004 005 127 128 133 134 255 Rotation motor 1 No rotation Cloc...

Page 15: ...Adjust sound sensitivity knob Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps re...

Page 16: ...ty CHAUVET reserves the right to use its own discretion to repair or replace product s FedEx packing or double boxing are recommended If you are given an RMA number please include the following inform...

Page 17: ...230 V 0 2 A max Power Linking 230 V 50 units LASER Green diode 532 nm 40 mW Red Diode 650 nm 100 mW Laser Type DPSS RANGE Coverage Angle 99 THERMAL Maximum ambient temperature 104 F 40 C Cooling Fan...

Reviews: