Troubleshooting 

If you experience low output, pump noise or no output at all, unplug immediately and do the following: 

1) 

Check fluid level, the external fuse, remote connection and main power supply. If all appear to 

be OK, plug the unit in again. 

2) 

If snow does not come out after holding the remote control button for 30 seconds, check the 

hose attached to the tank to make sure there is fluid going through the hose.  

3) 

If you are unable to determine the cause of the problem, do not simply continue to push the 

remote control button as this may damage the unit. Contact CHAUVET Technical Support at the 

location below.

 

Technical Support 

Address: Service Dept. 
3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.) 
Support (Email): tech@chauvetlighting.com 
Telephone: (954) 929-1115 - (Press 4) 
Fax: (954) 929-5560 - (Attention: Service) 
Website: http://www.chauvetlighting.com 

5.

 

A

PPENDIX

 

General Maintenance 

Warning:  

If your snow machine will be stored for more than 30 days, it must be purged before being 

stored. Failure to do so will void your warranty. To purge your fogger or snow machine, follow 

the instructions below. 

 

 

Your snow machine should be purged every 15 days to avoid build-up of particles in the system. To 

purge your snow machine, follow these instructions: 

 

1) 

Drain the unit of all fluid. 

 
2) 

Fill the tank with distilled water. 

 
3) 

Run the unit until all the distilled water is consumed (i.e. until the tank is dry). 

 
4) Store 

your 

unit. 

 

5) 

It is highly recommended that you run your unit with its respective fluid and then purge the 

system AT LEAST once every 30 days. 

SM-80 User Manual 

2006-12-13/15:33

 

Summary of Contents for SM-80

Page 1: ...ctivated DMX512 Master Slave 115V 230V Switch Replaceable Fuse User Serviceable Duty Cycle SM 80 Mini Snow Machine USER MANUAL Chauvet 3000 N 29th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com ...

Page 2: ...ION 5 FEATURES 5 PRODUCT OVERVIEW 5 3 SETUP 6 SNOW FLUID 6 FUSE REPLACEMENT 6 MOUNTING 6 Orientation 6 Rigging 6 4 OPERATING INSTRUCTIONS 7 MANUAL OPERATION 7 TIMER OPERATION 7 TROUBLESHOOTING 8 TECHNICAL SUPPORT 8 5 APPENDIX 8 GENERAL MAINTENANCE 8 RETURNS PROCEDURE 9 CLAIMS 9 TECHNICAL SPECIFICATIONS 9 SM 80 User Manual 2 2006 12 13 15 33 ...

Page 3: ...listed current rating is its average current draw under normal conditions All units must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a unit check that the source voltage matches the unit s requirement Warning Verify that the voltag...

Page 4: ...blocked Always disconnect from power source before servicing or replacing the fuse and be sure to replace with same fuse type and rating Secure unit to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate unit at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by your...

Page 5: ...rm up time Disperses snow over a large area Wired timer remote included Product Overview Manual Snow Button Handle Fluid Tank Nozzle At the rear Fuse holder Remote control socket Air volume knob Safety Hook Timer Remote SM 80 User Manual 5 2006 12 13 15 33 ...

Page 6: ...tting on a level surface or it may be mounted using the bracket provided Ensure that the snow is not shooting directly at anyone s face Whatever method of installation you choose the snow machine must not have more than a 15 degree angle of inclination tilt RIGGING Hanging Clamp It is important never to obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp Adjust t...

Page 7: ...remote control unit into the socket at the rear of the unit 2 On the rear of the unit choose desired air volume by adjusting the air volume knob 3 Press the power switch on the remote Red indicator light will illuminate to indicate unit is working 4 Press the TIMER button on the remote control to activate the timer 5 Use the INTERVAL knob to adjust the time period between outputting snow Clockwise...

Page 8: ...33020 U S A Support Email tech chauvetlighting com Telephone 954 929 1115 Press 4 Fax 954 929 5560 Attention Service Website http www chauvetlighting com 5 APPENDIX General Maintenance Warning If your snow machine will be stored for more than 30 days it must be purged before being stored Failure to do so will void your warranty To purge your fogger or snow machine follow the instructions below You...

Page 9: ...3 Your phone number 4 The RA 5 A brief description of the symptoms Claims Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping Any other claim for items such as missing co...

Reviews: