Setup
WELL™ Quad-M User Manual
-7-
3. Setup
AC Power
Each WELL™ Quad-M has an auto-ranging battery charger, whether stand-alone or
inside the flight case that works with an input voltage range of 100 to 240 VAC,
50/60 Hz. To determine the power requirements for each WELL™ Quad-M, refer to the
label affixed to the product. For more information, see the
Technical Specifications
section.
The listed current rating indicates the maximum current draw during normal operation.
For more information, you may download
Sizing Circuit Breakers
from the CHAUVET®
website:
www.chauvetpro.com
.
Always connect this product’s battery charger to a protected circuit with an
appropriate electrical ground to avoid the risk of electrocution or fire.
Never connect this product’s battery charger to a rheostat (variable resistor) or
dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100%
switch.
AC Plug
The WELL™ Quad-Ms battery charger comes with a power input cord terminated with
an Edison plug (US market). If the power input cord that came with your product has no
plug or you need to change the Edison plug, use the table below to wire the new plug.
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow or Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
Make sure to disconnect the product’s power cord before replacing a blown fuse.
Always replace the blown fuse with another of the same type and rating.
Fuse Replacement
The standalone battery charger has no external fuse. However, the
flight case/charger comes with a replaceable fuse
(T 6.3 A @ 250 V).
To change the fuse on the flight case/charger, do the following:
1. Disconnect the product from the power outlet.
2. With a Phillips #2 head screwdriver, unscrew the fuse holder
cap from its housing.
3. Remove the blown fuse and replace it with a good fuse of the
same type and rating (T 6.3 A @ 250 V).
4. Screw the fuse holder cap back in its place and reconnect
power.