47
Specific Specifications in MAX/MIN mode in Voltage
(from 10Hz to 1kHz in AC and AC+DC):
Accuracy: add 1% R to the values of the previous table.
Capture of the extreme: approximately 100ms.
Specific Specifications in PEAK mode
in voltage
(from 10Hz to 1kHz in AC and AC+DC):
Accuracy: add 1.5% R to the values in the previous table.
PEAK capture time: 1ms min. to 1.5ms max.
DC Current Measurement
4.2.4
Measurement
Range (2)
0.00 to
99.99A
100.0 to
999.9A
1000 to
3000A (1)
Specified
Measurement
Range
0 to 100% of the measurement range
Accuracy (2)
(zero corrected)
± (1% R +10cts) ± (1% R +3cts)
2000A
± (1.5% R +3 pt)
2000
to 2500A
DC
± (2.5% R +3 pt)
2500
to 3000A
DC
± (3.5% R +3 pt)
Resolution
0.01A
0.1A
1A
Note (1)
The display indicates “+OL” above 3000A.
Note (2)
The residual current at zero depends on the remanence. It can be
corrected by the “DC zero” function of the HOLD button.
AC Current Measurement
4.2.5
Measurement
Range (2)
0.15 to
99.99A
100.0 to
999.9A
1000 to
2000A (1)
Specified
Measurement
Range
0 to 100% of the measurement range
Accuracy
± (1% R +10cts)
± (1% R +3cts)
1000 to 1500A
± (1.5% R +3cts)
1500 to 2000A
± (2% R +5cts)
Resolution
0.01A
0.1A
1A
Note (1)
- The display indicates "OL" above 3000A (in PEAK mode). The "-" and
"+" signs are not managed.
-
Bandwidth in AC = 1 kHz
Note (2)
- In AC, any value between zero and the min. threshold of the
measurement range (0.15A) is forced to show “----“ on the display.
-
Residual current at zero <150mA.
Summary of Contents for AEMC 2139.61
Page 1: ...607 POWER CLAMP ON METER User Manual ENGLISH ...
Page 2: ...2 ...
Page 62: ......
Page 63: ......