20
AC voltages
(1)
Press the RANGE button.
Min measurement : 40mV
(2)
4000 count display limited to 600V
(3)
Use on frequency : 40Hz to 500Hz, except the
400mV range from 40Hz to 100Hz.
V AC
4 V
40 V
400 V
Digital
resolution
0.1 mV
1 mV
10 mV
100 mV
1 V
Bargraph
resolution
10 mV
100 mV
1 V
10 V
100 V
V AC
impedance
V elec
impedance
± 1.5 % reading ± 1 count
Permitted
overload
600 V rms and 900 V peak
270 k
Ω
600 V
(2)
400 mV
(1)
10 M
Ω
Accuracy
(3)
±5%R
Never test a resistance on a live circuit
■
Connect the leads to the multimeter and to the circuit or the component to
be tested.
■
Place the selector switch on the ohmmeter function
Ω
Press the
Ω
/ button to change from continuity sound test to resistance
measurement and vice versa.
■
Automatic range selection: read the measured value
■
Memorise the value, if necessary, by pressing the HOLD button.
If necessary, press the following buttons:
■
RANGE to select the range manually
■
MIN.MAX to read the min or max values
■
to light the display
CONTINUITY AND RESISTANCES