3
PRECAUTIONS FOR USE
This instrument complies with safety standard IEC/EN 61010-2-030 or BS EN 61010-2-030, the leads comply with IEC/EN 61010-
031 or BS EN 61010-031 for voltages of 1000 V in measurement category III or 600 V in measurement category IV and the current
sensors comply with IEC/EN 61010-2-032 or BS EN 61010-2-032.
Failure to observe the safety instructions may result in electric shock, fire, explosion, and destruction of the instrument and of the
installations.
The operator and/or the responsible authority must carefully read and clearly understand the various precautions to be taken
in use. Sound knowledge and a keen awareness of electrical hazards are essential when using this instrument.
For your safety, use only the compatible leads and accessories delivered with the instrument. When sensors or accessories
having a lower voltage rating and/or category are connected to the instrument, the lower voltage and/or category applies to
the system so constituted.
Before each use, check that the leads, enclosures, and accessories are in perfect condition. Any lead, sensor or accessory on
which the insulation is damaged (even partially) must be repaired or scrapped.
Do not use the instrument on networks of which the voltage or category exceeds those mentioned.
Do not use the instrument if it seems to be damaged, incomplete, or poorly closed.
Use only the AC power adapter supplied by the manufacturer.
When removing and replacing the SD-Card, make sure that the device is disconnected and switched off.
We recommend using Personal Protection Equipment where required.
Keep your hands away from unused terminals.
If the instrument is wet, dry it before connecting it.
All troubleshooting and metrological checks must be performed by competent and accredited personnel.
Summary of Contents for pel 102
Page 1: ...Power energy logger EN User s manual PEL 102 PEL 103 PEL 104 ...
Page 24: ...24 Aggregation period Date and time IP address scrolling Wi Fi address scrolling PEL104 ...
Page 36: ...36 Three phase 3 wire balanced 3P 3W b U12 U23 U31 f P Q S PF P Q S tan ϕ I1 I2 I3 ϕ I1 U12 ...
Page 38: ...38 Three phase 4 wire wye balanced 3P 4WYb I1 I2 I3 V1 V2 V3 VN U12 U23 U31 f P Q S tan ϕ ...
Page 39: ...39 DC 2 wire dC 2W DC 3 wire dC 3W P Q S PF ϕ I1 V1 P Q S tan ϕ P I V VN I1 I2 IN ...
Page 40: ...40 DC 4 wire dC 4W P I1 I2 I3 IN V1 V2 V3 VN V1 V2 VN ...
Page 48: ...48 Two phase 3 wire 1P 3W I1 I2 V1 V2 U12 VN P Q S P Q S ...
Page 51: ...51 P Q S ...
Page 85: ...85 ...