63
f) MN93A clamp
MN93A clamp
Nominal Range
5 A and 100 A
ac
M
N
9
3A
Measurement Range
5 A: 0.01 to 6 A
ac
max; 100 A: 0.2 A to 120 A
ac
max
Maximum Clamping Diameter
20 mm
Variation of the position of the
conductor in the clamp
< 0,5%, at 50/60 Hz
Adjacent conductor carrying
alternating current
> 35 dB typical at 50/60 Hz
Safety
IEC 61010-2-032, Pollution degree 2, 300 V CAT IV, 600 V CAT III
Table 19
The 5 A range of the MN93A is designed to work with secondary current transformers.
Note:
Currents < 2.5 mA x ratio on the 5 A range and < 50 mA on the 100 A range will be set to zero with this probe.
g) E3N clamp with adapter
E3N clamp
Nominal Range
10 A
ac/dc,
100 A
ac/dc
Measurement Range
0.01 to 100 A
ac/dc
Maximum Clamping Diameter
11.8 mm
Variation of the position of the
conductor in the clamp
< 0,5%
Adjacent conductor carrying
alternating current
> 33 dB typical, from DC to 1kHz
Safety
IEC 61010-2-032, Pollution degree 2, 300 V CAT IV, 600 V CAT III
Table 20
Note:
Currents < 50 mA will be set to zero in AC distribution systems.
h) J93 clamp
J93 clamp
Nominal Range
3500 A
ac,
5000 A
dc
Measurement Range
50 - 3500 A
ac
; 50 - 5000 A
dc
Maximum Clamping Diameter
72 mm
Variation of the position of the
conductor in the clamp
< ± 2%
Adjacent conductor carrying
alternating current
> 35 dB typical, from DC to 2 kHz
Safety
IEC 61010-2-032, Pollution degree 2, 600 V CAT IV, 1000 V CAT III
Table 21
Note:
Currents < 5 A will be set to zero in AC distribution systems.
Summary of Contents for pel 102
Page 1: ...Power energy logger EN User s manual PEL 102 PEL 103 PEL 104 ...
Page 24: ...24 Aggregation period Date and time IP address scrolling Wi Fi address scrolling PEL104 ...
Page 36: ...36 Three phase 3 wire balanced 3P 3W b U12 U23 U31 f P Q S PF P Q S tan ϕ I1 I2 I3 ϕ I1 U12 ...
Page 38: ...38 Three phase 4 wire wye balanced 3P 4WYb I1 I2 I3 V1 V2 V3 VN U12 U23 U31 f P Q S tan ϕ ...
Page 39: ...39 DC 2 wire dC 2W DC 3 wire dC 3W P Q S PF ϕ I1 V1 P Q S tan ϕ P I V VN I1 I2 IN ...
Page 40: ...40 DC 4 wire dC 4W P I1 I2 I3 IN V1 V2 V3 VN V1 V2 VN ...
Page 48: ...48 Two phase 3 wire 1P 3W I1 I2 V1 V2 U12 VN P Q S P Q S ...
Page 51: ...51 P Q S ...
Page 85: ...85 ...