SIMPLE LOGGER II
English
Page 46
MODEL
L562
Electrical
Inputs
Two
Input connections
BNC
Two 4 mm safety banana jacks
Input levels
0 to 1 V for use with sensor
delivering voltage output
0 to 600 V
AC/DC
Uncertainties (50 / 60 Hz)
Resolution
0 to 10 mV: unspecified
10 to 50 mV:
± (0,5% of r 1 mV)
50 to 1000 mV:
± (0,5% of r 0,5 mV)
0,1 mV
0 to 5 V: unspecified
5 to 50 V:
± (0,5% of r 1 V)
50 to 600 V:
± (0,5% of r 0,5 V)
0,1 V
Maximum input level ***
5 Vrms ± 7,07 Vpeak
1,2 X 600 V
Input impedance
800 k
Ω
40 M
Ω
Sample rate
64 samples/cycle
Storage rate
Programmable from 125 ms to 1 day
Storage modes
Start/Stop, FIFO and Extended Recording Mode* (XRM™)
Recording length
Programmable using DataView
®
from 15 minutes to 8 weeks
Memory
240,000 measurements (512 kB). The recorded data is stored in non-
volatile memory retained even if the battery is low or removed.
Communication
USB 2.0 optically isolated
Power source **
2 x 1.5 V AA (LR6) cell Alkaline batteries
Battery life
100 hours to >45 days (dependent on storage rate/recording length)
Mechanical
Dimensions
136x70x32 mm (5.38x2.75x1.28")
Weight (with batteries)
180 g (6.4 oz)
Case
UL94-V0
Vibration
IEC 68-2-6 (1.5 mm, 10 to 55 Hz)
Shock
IEC 68-2-27 (30 G)
Drop
IEC 68-2-32 (1 m)
Environmental
Operating temperature
- 10°C to + 50°C (14°F to 122°F)
Storage temperature
- 20°C to + 60°C (- 4°F to + 140°F)
Relative humidity
up to 85% at 35°C (95°F) without condensation
Altitude
2000 m
Safety
Conformity
EN61010-1; 600 V CAT III; 300 V CAT IV; Pollution level 2
Level of protection
IP 40
*See the end of chapter