CHCNAV ALPHAUNI 900 USER MANUAL
| 2020-06
P a g e | 23
1. Input Port (female head) 2. 24V Output Port (female head) 3. 12V Output Port (female head)
Number
1
2
3
4
5
6
Input Port Definition
/
/
Vin+
Vin-
RS485B-
24V Output Port
Definition
Vout+
Vout-
RS485B-
/
/
12V Output Port
Definition
Vout+
Vout-
/
/
/
/
4.2
Functional Specification
4.2.1
Orange Container Function
4.2.1.1
Orange Container Light Condition
When orange container is turn off, long-press switch button until buzzer sounds and display
screen shows battery information; Again, long-press switch button until buzzer sounds, and
orange container will turn off. If orange container is not used for a long time, it is
recommended to turn off it manually. Otherwise, it will turn off automatically after half hour
under light condition.
4.2.1.2
Orange Container Discharge Condition
The orange container will turn on automatically when it loads greater than 0.5A current and
the display screen will present battery information. Under load condition, the switch button
cannot work.
4.2.1.3
Orange Container Charge
The orange container is equipped with a 13.8V 7.2A battery charger for charge. It will turn on
automatically when it connects to charger with greater than 0.5A current and the display
screen will present battery information. Under charge condition, the switch button cannot
work. When charger light changes from red to green and charge current is 0A, it means the
battery is full charged.