Collecting System Diagnostics (smo verifiers)
Check Point Maestro R80.20SP Administration Guide | 155
Error Types
The
smo verifiers
detects these errors:
Error Type
Error
Description
System
health
Chassis <
X
> error
The Chassis quality grade is less than the defined
threshold.
We recommend that you correct this issue immediately.
Hardware
<
Component
> is
missing
The component is not installed in the Chassis.
<
Component
> is
down
The component is installed in the Chassis, but is inactive.
Resources
<
Resource
>
capacity
The specified resource capacity is not sufficient.
You can change the defined resource capacity.
<
Resource
> exceed
threshold
The resource usage is greater than the defined threshold.
CPU type
Non compliant CPU
type
At least one Security Appliance CPU type is not configured
in the list of compliant CPUs.
You can define the compliant CPU types.
Security
group
<
Source
> error
The information collected from this source is different
between the Security Appliances.
<
Sources
> differ
The information collected from many sources is different.