TROUBLESHOOTING
Harmonic images at 6000 and 4000 rpm are not a single still image, but double
and quadruple. Single image appears at 3000 and 1500 rpm. 1500 is half of
3000 and the same single image appears, therefore, the actual speed of the
object is 3000 rpm.
The Use of External Trigger
When in EXT mode: In this mode, the flash trigger signal frequency or
flash rate speed is automatically adjusted according to an external
sensor’s input signal.
Wiring of the external sensor is as follows:
1: +12 V dc up to 50 mA
2: Ground
3: Trigger signal 5 - 12 V dc
Issue
Troubleshooting Methods
Unit does not work and
no display
Check the power supply is proper
Power Switch is functioning
Whether internal fuse is burn out, check
and replace
Unit does not work but
displays properly
Silicon controlled rectifier / optical coupler
(IRF840/521-1) need replacement
Strobe flashtube needs to be replaced
Check if unit is in external trigger mode
Does not flash under
external trigger mode
Check if the trigger sensors are working
properly
Flashes intermittently
Flashtube needs to be replaced
Flash but the flash is
darker or dimmer than
typical
Actual Speed
RPM
Strobe
Frequency
FPM
Multiple
Number of
Still Images
3000
12,000
4
4
3000
9,000
3
3
3000
6,000
2
2
3000
3,000
1
1
3000
1,500
1/2
1
3000
1,000
1/3
1