159
Tabla de datos técnicos 1 - Datos nominales FLAME 9
Tipo
de gas
Gas type
Presión
nominal
ingreso
Nominal
inlet
pressure
(mbar)
Consumo
calorífico
nominal
Nominal
heat
input
(kW)
Consumo
calorífico
reducido
Reduced
heat
input
(kW)
Presión
de salida
válvula
(al MAX)
Valve
outlet
pressure
(at MAX)
(mbar)
Presión
de salida
válvula
(al MIN)
Valve
outlet
pressure
(at MIN)
(mbar)
Consumo del
gas al MAX
(con el poder
calorífico
inferior)
Gas
consumpion
at MAX (with
net calorific
value)
Regulador
de presión
Pressure
regulator
G20
20
29
17,5
10
3.6
3.07 m3/h
A
G20
25
29
17,5
10
3.6
3.07 m3/h
A
G25
20
29
17,5
15
5.5
3.57 m3/h
A
G25
25
29
17,5
15
5.5
3.57 m3/h
A
G25.1
25
29
17,5
17
6.2
3.56 m3/h
A
G25.3
25
29
17,5
13
4.5
3.489 m
3
/h
A
G30/G31
28-30/37
29
17,5
27.5
10
2.29/2.25 kg/h
B
G30,G31
50
29
17,5
27.5
10
2.29/2.25 kg/h
A
G30,G31
37
29
17,5
27.5
10
2.29/2.25 kg/h
A
A = Regulado en el funcionamiento al MAX y al MIN / Adjusted to MAX and MIN operating mode.
B = Regulado en el funcionamiento al MIN y fuera de servicio al MAX/ Adjusted to MIN operating mode and out
of service at MAX.
6.2.5
Conversión en otro tipo de gas
!
La conversión en otro gas se debe realizar por un técnico autorizado
El horno sale del fabricante listo para utilizar gas natural, salvo si se pride otra cosa por parte del cliente. El
equipamiento del horno comprende un kit de inyectores (boquillas) para poder adaptar el horno según el tipo
de gas (Gas líquido).
!
Antes de empezar con la conversión cerrar la alimentación del gas y desconectar
eléctricamente el horno.
Para poder realizar esta operación es necesario retirar el panel frontal inferior del horno, como se indica a
continuación:
1) Quitar las roscas que fijan el panel frontal
(parte marcada en la imagen);
2) Quitar el panel frontal para acceder al
inyector.
Summary of Contents for CHFPG4
Page 2: ...2...
Page 14: ...14 3 3 Schemi elettrici...
Page 15: ...15...
Page 47: ...47 3 3 Sch mas de c blage...
Page 48: ...48...
Page 80: ...80 3 3 Wiring diagrams...
Page 81: ...81...
Page 102: ...102 RU Category II2H3 Type of installation FLAME4 A1 B11 B21 FLAME 6 9 B11 B21...
Page 104: ...104 7 6 131 7 7 132 8 132 8 1 132 8 2 132 8 2 1 132 8 2 2 132 8 3 132 9 133 10 134...
Page 105: ...105 1 1 1 m 1 2 m 1 3 1 4...
Page 108: ...108 1 11 1 12 1 13 CE CE...
Page 109: ...109 RU 1 14 2 2 1...
Page 110: ...110 2 2 2 3...
Page 112: ...112 FLAME 9 148 126 47 105 105 15 196 18 220 230 50 60 50 3 x 0 75 2 B11 B21 I...
Page 113: ...113 3 3...
Page 114: ...114...
Page 116: ...116 4 25 50 50 m 5 5 1...
Page 117: ...117 5 2 25 50 50 6 6 1 4 2 F 6 2 6 2 1 3...
Page 118: ...118 6 2 1 1 6 2 2 1 13 1 5 6 2 3 A1 B11...
Page 119: ...119 B21 FLAME 4 FLAME 6 FLAME 9 B11 B11 A1 FLAME 4...
Page 123: ...123 FLAME 4 FLAME 6 45 6 2 4 6 3 1 EV1 2 EV2 3 Pin 4 Pout 5 6...
Page 124: ...124 1 0 1 E 2 3 Pin 6 7 3 Pin 3 4 Pout 4 B MAX 10 5 B MIN C D 6x1 E...
Page 130: ...130 A B C D E F G H 7 2 200 C 1 8 300 350 C 7 3 200 C A 1 D B 0 B 1 7 4...
Page 131: ...131 7 5 380 C 3 3 5 1 30 40 380 2 3 4 5 B 0 B 1 20 7 6 H 1...
Page 132: ...132 7 7 D 0 A 0 8 8 1 89 391 8 2 8 2 1 350 60 100 C 8 2 2 8 3...
Page 133: ...133 9 0 1 1 PF Schuko...
Page 134: ...134 10 13 151 25 2005 2002 95 2002 96 2003 108...
Page 146: ...146 3 3 Esquemas el ctricos...
Page 147: ...147...
Page 179: ...179 3 3 Schaltpl ne...
Page 180: ...180...
Page 201: ...201 EXPLODED VIEW DRAWINGS AND SPARE PARTS...
Page 202: ...202...
Page 203: ...203...
Page 209: ...209 ROTATING DOOR SYSTEM LAMP SYSTEM...
Page 210: ...210 ANALOGUE THERMOMETER CONTROLS DIGITAL THERMOMETER CONTROLS...
Page 211: ...211...