Electric Induction hobs Chef’s EH-XXX533
21
In case of the temp. limit (electronics or coil) of a cooking zone in booster
operation is exceeded, the booster is cut off automatically. The cooking zone is
reset to nominal power.
As long as one of the two temp. limits remains exceeded, the booster may not
be activated. In this case the booster is indicated on the cooking zone display
while the booster key is pressed. After that automatic cooking stage reduction is
displayed.
The residual heat indication is reported from the slave to the TC via LIN-BUS
(induction and mixed systems). Possible optic warnings for hot cooking zones [H]
are displayed without double check by Touch Control.
9.
Dual Circuit Activation ( Radiant cooking)
The control unit may trigger (on EH-MIX533 type) dual circuit. Dual Circuits
are switched automatically on after activating a cooking zone.
Activation/Deactivation of dual circuit on radiant burner
By pressing on the dual-circuit key “+b” the respective double or outer circuit
is activated on radiant burner.
Re-press the dual-circuit key “+b” to deactivates the outer circuit .
An active double or outer circuit is also shown by the assigned LED is
statically illuminated.
Fig. 11: Select outer circuit of radiant burner by press on “+b” key.