1.0 05/05/2013
13
If the unstable state of the input voltage exceeds the allowable limits, it is impossible
then for the machine tool to achieve the rated horsepower of the machine tool. The machine
tool can be running normally, but it is in no way to transfer the power as indicated.
The reliable ground is a guarantee for the personal safety and the safe operation of
the machine. When the user Introduces the power line for the machine tool, the protective
grounding wires shall be first connected and the grounding wire specifications shall not be less
than the power line specifications. The ground wires shall not be connected to the cooling water
pipe or the ground rod close to the machine tool.
The power inputted into the machine tool shall be grounded.
The user shall check the ground wires to find out whether they are reliable.
3.Installation
Safe Installation
Read the Operation Instructions, so as to master the operation of the machine!
Warning! Throughout the overall installation process, protective glasses shall be worn !
This Is a heavy miniature machine tool. When unpacking or moving the machine,
there shall be a helper.
3.1 Tools Required for Installation
Here are the tools needed to complete the installation, but they are not included in your
machine packaging.
Name
Q’ty
Name
Q’ty
Protective glasses (for each
operator)
1
6 mm flat washers
(required
for fixation on countertop)
4
Towel
1
Electric drill (required for
fixation on countertop)
1
Cleaner
1
Drill bit (8mm) (required for
fixation on countertop)
1
Level meter (required for
fixation on countertop)
1
No. 2 flat head screwdriver
1
M6 hexagon bolt (used for
fixation,
length
determined
according to the thickness of
the countertop) (required for
fixation on countertop)
4
Flathead screwdriver
1
Unpacking wrench
(
14mm
)
1
3.2 Unpacking