1.0 05/05/2013
37
8.2 Electrical Maintenance Shown in Figures
Step one
Fig.1 Fig.2
Fig.3 Fig.4
1.QKS7 plays the role of a switch in function, from which it is required to introduce two 1mm
2
lines. One end of one line of the two lines is required to press the terminal and the other end
shall be not required to press the terminal (as shown in Fig.1).
2. For the internal wiring mode of QKS7, Connect the two terminals below (as shown in Fig.2).
3. Connection mode of plug wires and lines introduced from QKS. The plug wires are
composed of such three colors of wires as blue, green yellow and purple and the green yellow
wire shall not be connected temporarily, as there is no wire of terminal in the lines introduced
from QKS, which can be connected with the blue wire of the plug wires (as shown in Fig.3).
4.
The plug wires and the switch QKS are connected completely (as shown in Fig.4).