7-434
Power Outlets
module remains OFF, until the AC powered device is
unplugged from the outlet, and then plugged into
the outlet after a 3 s delay.
230 Volt Power Outlet Receptacle
Overload Shutdown
The accessory AC/DC power control module will turn
OFF if the current in the 230 V circuit is greater than
3.8 A for 1 second, or 2.5 A for 10 seconds. The module
will turn ON again, when the AC powered device is
unplugged from the outlet, and then plugged into the
outlet after a 3 second delay.
230 Volt Power Outlet Receptacle
Internal Shutdown
The accessory DC/AC power inverter module will turn
OFF if the B+ supply voltage is greater than 16.5 V or
less than 11 V. The module will also turn OFF if the
device temperature is greater than 85°C (185°F). The
module will turn ON again, after the shutdown condition
is corrected, and the AC powered device is unplugged
from the accessory power receptacle
–
220V AC, and
then plugged into the accessory power receptacle
–
220V AC.
2021 - Silverado 4500HD, 5500HD, and 6500HD Electrical Body Builder Manual