Page 10
For technical questions, please call 1-888-866-5797.
Item 44677
NOTICE
Clean the Spray Gun IMMEDIATELY after EVERY use.
Delayed or inadequate cleaning will permanently clog the Spray Gun.
Latex paint hardens quickly and permanently inside Spray Gun.
Operation
Fluid Tip Selection
The choice of Fluid Tip Set will vary according to the consistency of the fluid being sprayed. Consult paint
manufacturer recommended spray tips and use Table A to select a Tip Set appropriate to the job.
Table A: Fluid Tip Set Suggestions
Moves Like
Consistency
Examples
Suggested Tip Sets in mm
Sugar Water,
Simple Syrup
Light
Automotive Lacquers, Thin Woodworking,
Clear Coats with a VOC of 3.5 or Higher
1.0-1.3
Room
Temperature
Pancake Syrup
Medium
Wood Standard Lacquers and Enamels,
Clear Coats with a VOC of 2.1 or Lower,
Primer Sealing Coats and Urethane
1.5-1.8
Note: Chart provided for reference only. Additional fluid tips sizes not included.