background image

Page 7

For technical questions, please call 1-888-866-5797.

Item 62397 

        

SAFET

y

O

PERA

TION

M

AINTENANCE

SETUP

Extension Cords

1. 

Grounded

 tools require a three wire extension cord.  

Double Insulated

 tools can use either 

a two or three wire extension cord.

2.  As the distance from the supply outlet increases, 

you must use a heavier gauge extension cord.  

Using extension cords with inadequately sized wire 

causes a serious drop in voltage, resulting in loss of 

power and possible tool damage.  

(See Table A.)

3.  The smaller the gauge number of the wire, the 

greater the capacity of the cord.  For example, 

a 14 gauge cord can carry a higher current 

than a 16 gauge cord.  

(See Table A.)

4.  When using more than one extension cord 

to make up the total length, make sure 

each cord contains at least the minimum 

wire size required.  

(See Table A.)

5.  If you are using one extension cord for more 

than one tool, add the nameplate

 

amperes 

and use the sum to determine the required 

minimum cord size.  

(See Table A.)

6.  If you are using an extension cord outdoors, make 

sure it is marked with the suffix “W-A” (“W” in 

Canada) to indicate it is acceptable for outdoor use.

7.  Make sure the extension cord is properly wired 

and in good electrical condition.  Always replace 

a damaged extension cord or have it repaired 

by a qualified electrician before using it.

8.  Protect the extension cords from sharp objects, 

excessive heat, and damp or wet areas.

TABLE A:  RECOMMENDED MINIMUM WIRE 

GAUGE FOR EXTENSION CORDS* (120/240 VOLT)

NAMEPLATE

AMPERES

(at full load)

EXTENSION CORD 

LENGTH

25´ 50´ 75´ 100´

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

* Based on limiting the line voltage drop to five volts at 

150% of the rated amperes.

Symbology

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V

Volts

~

Alternating Current

A

Amperes

n0 xxxx/min.

No Load Revolutions per Minute (RPM)

WARNING marking concerning Risk 

of Eye Injury.  Wear ANSI-approved 

safety goggles with side shields.

Read the manual before 

set-up and/or use.

WARNING marking 

concerning Risk of Fire.  

Do not cover ventilation ducts.

Keep flammable objects away.

WARNING marking concerning 

Risk of Electric Shock.  

Properly connect power cord 

to appropriate outlet.
WARNING marking concerning 

Risk of Hearing Loss.  

Wear hearing protection.

Summary of Contents for 62397

Page 1: ...and dry place for future reference When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2014 b...

Page 2: ...ion which if not avoided could result in minor or moderate injury Addresses practices not related to personal injury IMPORTANT SAFETY INFORMATION General Power Tool Safety Warnings Read all safety war...

Page 3: ...imes This enables better control of the power tool in unexpected situations 5 Dress properly Do not wear loose clothing or jewelry Keep your hair clothing and gloves away from moving parts Loose cloth...

Page 4: ...eep it out of reach of children 15 People with pacemakers should consult their physician s before use Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or...

Page 5: ...le who have impaired blood circulation to the hand past hand injuries nervous system disorders diabetes or Raynaud s Disease should not use this tool If you feel any symptoms related to vibration such...

Page 6: ...to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet 2 The grounding prong in the plug is connected through the green wire inside the cord to the gro...

Page 7: ...a to indicate it is acceptable for outdoor use 7 Make sure the extension cord is properly wired and in good electrical condition Always replace a damaged extension cord or have it repaired by a qualif...

Page 8: ...l questions please call 1 888 866 5797 Item 62397 Safety Operation Maintenance Setup Specifications Electrical Input 120 VAC 60 Hz 12 5 A Blows Per Minute 1900 BPM Chisels Sold Separately Chuck SDS MA...

Page 9: ...INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product Note For additional information regarding the parts listed in the...

Page 10: ...power cord to possible damage The power cord must reach the work area with enough extra length to allow free movement while working 3 Secure loose work pieces using a vise or clamps not included to pr...

Page 11: ...pect the general condition of the tool Check for loose hardware misalignment or binding of moving parts damaged cord electrical wiring dull or cracked Chisel cracked or broken parts and any other cond...

Page 12: ...erformance decreases over time 1 Accessory dull or damaged 2 Carbon brushes worn or damaged 1 Keep cutting accessories sharp Replace as needed 2 Have qualified technician replace brushes Excessive noi...

Page 13: ...IED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS...

Page 14: ...y 1 43 Boring Washer 2 44 Needle Bearing Rmao16 22 16 2 45 Needle Ferrule 1 46 Needle Bearing Nk20 28 13 1 47 Seal Ring Subassembly 2 48 Housing 1 49 Cord Clip 1 50 St4 2 18 Tapping Screw 4 52 Main Ha...

Page 15: ...5 16 8 9 10 6 7 4 5 1 2 36 37 38 40 41 42 43 44 45 43 39 26 25 24 23 22 21 20 18 19 18 17 33 32 31 26 30 29 28 35 74 76 77 79 80 81 82 81 80 83 84 85 86 87 72 73 92 93 94 95 97 98 96 75 74A 78 55 52 3...

Page 16: ...the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPL...