background image

Page 6

For technical questions, please call 1-800-444-3353.

SKU 91222

1.  Anyone using vibrating tools regularly or for an 

extended period should first be examined by a 

doctor and then have regular medical check-

ups to ensure medical problems are not being 

caused or worsened from use.  Pregnant women 

or people who have impaired blood circulation 

to the hand, past hand injuries, nervous system 

disorders, diabetes, or Raynaud’s Disease should 

not use this tool.  If you feel any medical or 

physical symptoms related to vibration (such as 

tingling, numbness, and white or blue fingers), 

seek medical advice as soon as possible.

2.  Do not smoke during use.  Nicotine reduces 

the blood supply to the hands and fingers, 

increasing the risk of vibration-related injury.

3.  Wear suitable gloves to reduce the 

vibration effects on the user.

4.  Use tools with the lowest vibration when there 

is a choice between different processes.

5.  Include vibration-free periods each day of work.

6.  Grip tool as lightly as possible (while still keeping 

safe control of it).  Let the tool do the work.

7.  To reduce vibration, maintain the tool as 

explained in this manual.  If any abnormal 

vibration occurs, stop use immediately.

  SAVE THESE 

INSTRUCTIONS. 

 

 

Grounding

TO PREVENT ELECTRIC SHOCK AND 

DEATH FROM INCORRECT GROUNDING 

WIRE CONNECTION: 

Check with a qualified electrician if you are 

in doubt as to whether the outlet is properly 

grounded.  Do not modify the power cord plug 

provided with the tool.  Never remove the grounding 

prong from the plug.  Do not use the tool if the power 

cord or plug is damaged.  If damaged, have it 

repaired by a service facility before use.  If the plug 

will not fit the outlet, have a proper outlet installed by 

a qualified electrician.

Grounded Tools:  

Tools with Three Prong Plugs

3-Prong Plug and Outlet

1.  Tools marked with “Grounding Required” have a three 

wire cord and three prong grounding plug.  The plug 

must be connected to a properly grounded outlet.  

If the tool should electrically malfunction or break 

down, grounding provides a low resistance path to 

carry electricity away from the user, reducing the risk 

of electric shock.  

(See 3-Prong Plug and Outlet.)

2.  The grounding prong in the plug is connected through 

the green wire inside the cord to the grounding 

system in the tool.  The green wire in the cord must 

be the only wire connected to the tool’s grounding 

system and must never be attached to an electrically 

“live” terminal.  

(See 3-Prong Plug and Outlet.)

3.  The tool must be plugged into an appropriate outlet, 

properly installed and grounded in accordance with 

all codes and ordinances.  The plug and outlet should 

look like those in the preceding illustration.   

(See 3-Prong Plug and Outlet.)

Double Insulated Tools:  

Tools with Two Prong Plugs

Outlets for 2-Prong Plug

1.  Tools marked “Double Insulated” do not 

require grounding.  They have a special 

double insulation system which satisfies 

OSHA requirements and complies with 

the applicable standards of Underwriters 

Laboratories, Inc., the Canadian Standard 

Association, and the National Electrical Code.

Summary of Contents for 91222

Page 1: ...orfreight com Email our technical support at tech harborfreight com Copyright 2004 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual product may differ...

Page 2: ...ery operated cordless power tool 1 Work area safety a Keep work area clean and well lit Cluttered or dark areas invite accidents b Do not operate power tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Power tools create sparks which may ignite the dust or fumes c Keep children and bystanders away while operating a power tool Distractions can cause you to lo...

Page 3: ...unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrained users e Maintain power tools Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the power tool s operation If damaged have the power tool repaired before use Many accidents are caused by poorly maintained power t...

Page 4: ... draw the dust inside the housing and excessive accumulation of powdered metal may cause electrical hazards 15 Do not operate the power tool near flammable materials Sparks could ignite these materials 16 Do not use accessories that require liquid coolants Using water or other liquid coolants may result in electrocution or shock 17 Maintain labels and nameplates on the tool These carry important s...

Page 5: ... loss of control Safety Warnings Specific for Grinding Operations 1 Use only wheel types that are recommended for your power tool and the specific guard designed for the selected wheel Wheels for which the power tool was not designed cannot be adequately guarded and are unsafe 2 The guard must be securely attached to the power tool and positioned for maximum safety so the least amount of wheel is ...

Page 6: ...power cord plug provided with the tool Never remove the grounding prong from the plug Do not use the tool if the power cord or plug is damaged If damaged have it repaired by a service facility before use If the plug will not fit the outlet have a proper outlet installed by a qualified electrician Grounded Tools Tools with Three Prong Plugs 3 Prong Plug and Outlet 1 Tools marked with Grounding Requ...

Page 7: ... you are using one extension cord for more than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Table A 6 If you are using an extension cord outdoors make sure it is marked with the suffix W A W in Canada to indicate it is acceptable for outdoor use 7 Make sure the extension cord is properly wired and in good electrical condition Always replace a ...

Page 8: ...the planned work 4 Tighten the Wheel Guard Nut securely 5 Check the Wheel Guard to ensure it is firmly in place Adjust if necessary before proceeding Installing the Side Handle TO PREVENT SERIOUS INJURY Do not operate this tool with one hand only or without the Side Handle properly installed 6 The Side Handle may be installed in one of two positions on either side of the Gear Housing 7 Screw the t...

Page 9: ...he wheel with a light non metallic object such as a screwdriver handle at a point 45 from the vertical center line on each side of the wheel and 1 2 inches from the edge of the wheel see Illustration c Rotate the wheel 90 and repeat the test until the entire wheel has been checked d An undamaged wheel will give a clear tone If cracked there will be a dead sound and not a clear ring 6 For wheels wi...

Page 10: ...d to prevent movement while working 4 There must not be hazardous objects such as utility lines or foreign objects nearby that will present a hazard while working 5 You must use personal safety equipment including but not limited to ANSI approved eye and hearing protection as well as heavy duty work gloves 6 Before beginning work provide for sparks and debris that will fly off the work surface Gen...

Page 11: ...clean cloth 3 Periodically blow dust and grit out of the motor vents using dry compressed air Wear ANSI approved safety goggles and NIOSH approved breathing protection while doing this 4 WARNING If the supply cord of this power tool is damaged it must be replaced only by a qualified service technician Carbon Brush Replace the carbon brush when it wears down to about 3 16 5 mm or sparking will occu...

Page 12: ...y goggles and NIOSH approved dust mask respirator while blowing dust out of motor using compressed air 3 Eliminate use of extension cord If an extension cord is needed use one with the proper diameter for its length and load See Extension Cords in GROUNDING section Tool does not grind sand or brush effectively 1 Disc accessory may be loose on Spindle Check tightness of Outer Flange Arbor Nut or th...

Page 13: ...in 1 13 Pinion 1 14 Ball Bearing 1 15 Armature 1 Part Description Qty 16 Ball Bearing 1 17 Stator 1 18 Housing 1 19 Slide Switch 1 20 Slide Bar 1 21 Brush Holder 1 22 Carbon Brush 1 23 Brush Cap 1 24 Cord 1 25 Cover 1 26 Switch 1 27 Switch Holder 1 28 Wrench 1 29 Side Handle 1 29 Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead Note...

Page 14: ...ental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must...

Page 15: ......

Page 16: ...3491 Mission Oaks Blvd PO Box 6009 Camarillo CA 93011 800 444 3353 ...