Page 10
SKU 94191
for technical questions, please call 1-800-444-3353.
Grounding The Generator:
GROuNdING TERMINAl
(9)
#6 AWG GROuNdING WIRE
(NOT INcludEd)
GROuNdING ROd
(NOT INcludEd)
fIGuRE c
Note:
It is recommended that only a trained and licensed electrician perform this proce-
dure.
Connect a #6 AWG grounding wire (not included) from the Grounding Terminal (9)
on the Generator to a grounding rod (not included) that has been driven at least
24
inches
deep into the earth. The grounding rod must be an earth-driven copper or
brass rod (electrode) which can adequately ground the Generator.
(See figure c.)
cONTROl PANEl fEATuRES
Engine Ignition (2):
1.
Starts and stops the Gasoline Engine. To start the Engine
using power from the Battery (45), insert the Ignition Key (65) and turn the Engine
Ignition to its
“START”
position. To start the Engine manually using the Starter Rope
(40A) and Starter Handle (41A), insert the Ignition Key and turn the Engine Ignition
to its
“RuN”
position. Then pull briskly on the Starter Handle. To stop the Engine,
turn the Engine Ignition to its
“Off”
position.
Always remove the Ignition Key
when the Generator is not in use.
(See figure d, next page.)
fuel Tank cap (34):
2.
NEVER
run the Engine with the Fuel Tank Cap removed.
(See figure d.)
120 Volt Ac Outlets (5):
3.
The Generator is equipped with two 3-hole 120 volt AC
outlets to power 120 volt tools and equipment.
(See figure d.)