GENERATOR MAiNTENANcE
Keep the Generator clean and dry at all times.
1.
The Generator should not be operated or stored in locations that include exces-
2.
sive moisture, dust, flammable or corrosive vapors. If these substances are on the
Generator, clean with a soft cloth or brush.
Do not use a garden hose or anything with liquid to clean the Generator. Liquid
3.
may enter the cooling air slots and could damage the interior workings of the Gen-
erator.
ENGiNE MAiNTENANcE
After the first 5 to 8 hours of use:
1.
Change the oil. Then, change the oil every
50 hours of use. Change the oil every 25 hours of use when operating the Engine
under a heavy load or in high temperatures.
PLuG (59A)
OiL diPSTicK (65A)
FiGuRE G
2. To change the oil, remove the Plug (59A) and allow the old oil to drain in a proper
container. Once drained, replace the Plug.
(See Figure G.)
NOTE:
3.
If the Engine will be run in temperatures above 32 degrees Fahrenheit,
use
SAE 30
weight oil. If the Engine will be run in temperatures below 32 degrees
Fahrenheit, use
SAE 5W-30
weight oil.
To add engine oil, unscrew and remove the Oil Dipstick (65A). Pour engine oil into
4.
the Dipstick Hole until the level of oil is even with the top edge of the Dipstick Hole.
Then, make sure to screw the Oil Dipstick back into its Dipstick Hole.