background image

1

964.759.00.0 (00)

Geberit Tessera

TM

Toilet System

INSTALLATION INSTRUCTIONS

Geberit Manufacturing, Inc.

1100 Boone Drive, Michigan City, IN 46360

www.us.geberit.com

Phone: 219 / 879-4466 • Fax: 219 / 872-8003

For Technical Assistance 800 / 225-7217

2100 Clearwater Drive, Des Plaines, IL 60018-5999
www.chicagofaucets.com
Phone: (847) 803 5000 • Fax: (847) 298-3101
For Technical Assistance 800 / TEC-TRUE (800-832-8783)

Copyrights

© 2005 Geberit. All rights reserved. The information in this
manual is subject to change without notice.

Notice to Installers

Please leave this manual with the facility manager after completing
the Tessera

TM

Toilet System Installation. This document contains

information necessary for routine maintenance and servicing.

TABLE OF CONTENTS

Product Overview....................................................

2

Features...................................................................

2

In Compliance with..................................................

2

Available Options.....................................................

2

How to Order............................................................ 2

Technical Support..................................................... 2

Product Specifications.............................................. 2

Installation Requiremenst.......................................... 2

Safety Information...................................................... 3

Dimensions............................................................. 3-4

Tank & Carrier Installation....................................... 4-5

Wall Hung Bowl Installation.................................... 6-7

Access Panel Flush Actuator Installation............... 8-9

Component Identification.................................... 10-11

Troubleshooting Guide............................................. 12

Warranty.................................................................... 12

ADA Compliant

Summary of Contents for Geberit Tessera

Page 1: ...is manual is subject to change without notice Notice to Installers Please leave this manual with the facility manager after completing the TesseraTM Toilet System Installation This document contains information necessary for routine maintenance and servicing TABLE OF CONTENTS Product Overview 2 Features 2 In Compliance with 2 Available Options 2 How to Order 2 Technical Support 2 Product Specifica...

Page 2: ... condensation IN COMPLIANCE WITH ASME 112 19 2 ASME 112 6 2 CSA B125 ASSE 1002 AVAILABLE OPTIONS White wall hung bowl 111 870 DY 1 Bone wall hung bowl 111 870 AA 1 Biscuit wall hung bowl 111 870 FF 1 White closed front seat 113 050 DY 1 Bone closed front seat 113 050 AA 1 Biscuit closed front seat 113 050 FF 1 Tile cushion pad 156 055 00 1 Remote Flush Actuator 115 941 XX 1 Access panel drywall 11...

Page 3: ...oard Ceramic tile surface Total thickness not to exceed 2 R H 15 to 19 380 482 22 558 61 2 165 95 8 245 1 2 UNC 12 305 SAFETY INFORMATION Read this entire instruction sheet to ensure proper installation Compliance and conformity to local building codes and ordinances is the responsibility of the installer Compliance and conformity to local fire codes and ordinances is the responsibility of the ins...

Page 4: ...plate and floor to clear passage for discharge fitting at required location 3 Place the carrier assembly in the prepared opening 4 THE CARRIER FRAME MUST BE FLUSH WITH THE FRONT OF THE SUPPORTING STUDS to provide maxi mum support for the wall surface material applied later 5 Mark the 6 anchor hole locations on the sole plate and the 6 bolt hole location 3 each side on the studs 6 Remove the carrie...

Page 5: ...alve in shut off position du not connect fill valve supply hose until the installation is completet 4 1 2 3 5 6 1 Attach and secure mud guard onto tank access window 2 Install tank access cover plate snap in 3 Install blue mud guard cover snap on 1 Install two 2 1 2 x 6 threaded rods A supplied into the tank carrier frame extending approximately 4 from frame 2 Install protective clear plastic slee...

Page 6: ...ce a straight edge flush against the wall and across the fill pipe and mark dimension A Repeat for discharge adaper 5 Remove inlet and discharge adapters from tank carrier assembly 1 Install the inlet and discharge adapters with gaskets fully into the bowl 2 Measure and mark dimension B on both pipes 3 Remove pipes and gaskets from bowl 1 Add dimensions A and B then subtract 1 8 to get dimension C...

Page 7: ...vided Do not use plumbers putty or Silicone sealant 2 Install both adapters into appropriate wall side hub 1 Place the bowl onto the fixture rods 2 Install cap retainers 1 washers 2 and nuts 3 Secure bowl with nuts handtight only Note Cap retainers 1 should be installed with the larger end facing up 3 Level the bowl then tighten nuts DO NOT OVERTHIGTEN NUTS 4 Snap caps over cap retainers 4 3 1 up ...

Page 8: ...Tank water level WL must be 3 4 below over flow level OFL 2 1 Remove mud guard cover 2 Trim off excess material to be flush with wall 3 Discard cover and excess material Lift out cover plate 4 5 1 Install two 2 threaded lock pins part of actuator assembly 2 Adjust lock pin length to be flush with finished wall turn to lock in place 1 Reset cover plate in tank opening interlock with two 2 bracket s...

Page 9: ...nstall rod and tum clockwise to lock it into the bushing 9 7 1 Place actuator frame onto front of box with spring at the bottom facing outward 2 Secure frame onto lock pins with two 2 self tapping screws provided A C B push 1 To complete the installation attach the actuator plate on to spring at lower side push up and snap the upper edge onto frame 2 Secure actuator plate to frame test for functio...

Page 10: ...s clogged Hex nuts are not tighten appropriately Improper wall surface used to mount bowl Gypsum green board cement board tile backer board or ceramic tile surface are recommended materials for mounting Excess length of air tube used in installa tion tube is too long to allow sufficient air to reach from push button to lifter assembly Air tube is kinked or pinched Air tube connections loose Lifter...